The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Automated Polyp Detection in Colon Capsule Endoscopy
Open accessAbstract
Colorectal polyps are important precursors to colon cancer, a major health problem. Colon capsule endoscopy is a safe and minimally invasive examination procedure, in which the images of the intestine are obtained via digital cameras on board of a small capsule ingested by a patient. The video sequence is then analyzed for the presence of polyps. We propose an algorithm that relieves the labor of a human operator analyzing the frames in the video sequence. The algorithm acts as a binary classifier, which labels the frame as either containing polyps or not, based on the geometrical analysis and the texture content of the frame.We assume that the polyps are characterized as protrusions that are mostly round in shape. Thus, a best fit ball radius is used as a decision parameter of the classifier. We present a statistical performance evaluation of our approach on a data set containing over 18 900 frames from the endoscopic video sequences of five adult patients. The algorithm achieves 47% sensitivity per frame and 81% sensitivity per polyp at a specificity level of 90%. On average, with a video sequence length of 3747 frames, only 367 false positive frames need to be inspected by an operator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
Jemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., & Forman, D. (2011) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20107 · Cited by 54,679
The random subspace method for constructing decision forests
Ho, T. K. (1998) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.709601 · Cited by 6,842
Haralock, R. M., & Shapiro, L. G. (1991) · Addison-Wesley Longman Publishing Co., Inc. eBooks · Cited by 3,933
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Scale-Space Theory in Computer Vision
Lindeberg, T. (1994) · Springer eBooks · doi:10.1007/978-1-4757-6465-9 · Cited by 2,169
Three-dimensional computer-aided diagnosis scheme for detection of colonic polyps
Yoshida, H., & Nappi, J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974921 · Cited by 343
Eliakim, R., Yassin, K., Niv, Y., Metzger, Y., Lachter, J., Gal, E., Sapoznikov, B., Konikoff, F., Leichtmann, G., Fireman, Z., et al. (2009) · Endoscopy · doi:10.1055/s-0029-1215360 · Cited by 342
Capsule endoscopy: progress update and challenges ahead
Moglia, A., Menciassi, A., Dario, P., & Cuschieri, A. (2009) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2009.69 · Cited by 180
Cited by
PraNet: Parallel Reverse Attention Network for Polyp Segmentation
Fan, D.-P., Ji, G.-P., Zhou, T., Chen, G., Fu, H., Shen, J., & Shao, L. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-59725-2_26 · Cited by 1,499
Automated Polyp Detection in Colonoscopy Videos Using Shape and Context Information
Tajbakhsh, N., Gurudu, S. R., & Liang, J. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2487997 · Cited by 1,203
KVASIR: A Multi-Class Image Dataset for Computer Aided Gastrointestinal Disease Detection
Pogorelov, K., Randel, K. R., Griwodz, C., Eskeland, S. L., de Lange, T., Johansen, D., Spampinato, C., Dang-Nguyen, D.-T., Lux, M., Schmidt, P. T., et al. (2017) · Proceedings of the 8th ACM on Multimedia Systems Conference · doi:10.1145/3083187.3083212 · Cited by 684
Polyp-PVT: Polyp Segmentation with Pyramid Vision Transformers
Dong, B., Wang, W., Fan, D.-P., Li, J., Fu, H., & Shao, L. (2023) · CAAI Artificial Intelligence Research · doi:10.26599/air.2023.9150015 · Cited by 530
Application of Artificial Intelligence to Gastroenterology and Hepatology
Le Berre, C., Sandborn, W. J., Aridhi, S., Devignes, M.-D., Fournier, L., Smaïl-Tabbone, M., Danese, S., & Peyrin-Biroulet, L. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.08.058 · Cited by 516
Metadata
- Authors
- Mamonov, A. V., Figueiredo, I. N., Figueiredo, P. N., & Richard Tsai, Y.-H.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2014-07
- Volume
- 33
- Issue
- 7
- Pages
- 1488-1502
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2077474654
- Cited by
- 292
- References
- 23
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Polyp Detection in Colon Capsule Endoscopy. https://app.cochat.ai/papers/10.1109/tmi.2014.2314959
- The paper
- Mamonov, A. V., Figueiredo, I. N., Figueiredo, P. N., & Richard Tsai, Y.-H. (2014). Automated Polyp Detection in Colon Capsule Endoscopy. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2014.2314959
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.