Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 298

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Macular OCT Classification Using a Multi-Scale Convolutional Neural Network Ensemble

Rasti, Reza, Rabbani, Hossein, Mehridehnavi, Alireza, Hajizadeh, Fedra · 2018 · IEEE Transactions on Medical Imaging

Abstract

Computer-aided diagnosis (CAD) of retinal pathologies is a current active area in medical image analysis. Due to the increasing use of retinal optical coherence tomography (OCT) imaging technique, a CAD system in retinal OCT is essential to assist ophthalmologist in the early detection of ocular diseases and treatment monitoring. This paper presents a novel CAD system based on a multi-scale convolutional mixture of expert (MCME) ensemble model to identify normal retina, and two common types of macular pathologies, namely, dry age-related macular degeneration, and diabetic macular edema. The proposed MCME modular model is a data-driven neural structure, which employs a new cost function for discriminative and fast learning of image features by applying convolutional neural networks on multiple-scale sub-images. MCME maximizes the likelihood function of the training data set and ground truth by considering a mixture model, which tries also to model the joint interaction between individual experts by using a correlated multivariate component for each expert module instead of only modeling the marginal distributions by independent Gaussian components. Two different macular OCT data sets from Heidelberg devices were considered for the evaluation of the method, i.e., a local data set of OCT images of 148 subjects and a public data set of 45 OCT acquisitions. For comparison purpose, we performed a wide range of classification measures to compare the results with the best configurations of the MCME method. With the MCME model of four scale-dependent experts, the precision rate of 98.86%, and the area under the receiver operating characteristic curve (AUC) of 0.9985 were obtained on average.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2017.2780115

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Cited by

See all 298

Metadata

Authors
Rasti, R., Rabbani, H., Mehridehnavi, A., & Hajizadeh, F.
Venue
IEEE Transactions on Medical Imaging
Published
2018-04
Volume
37
Issue
4
Pages
1024-1034
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2773475231
Cited by
298
References
46
FWCI
12.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Macular OCT Classification Using a Multi-Scale Convolutional Neural Network Ensemble. https://app.cochat.ai/papers/10.1109/tmi.2017.2780115
The paper
Rasti, R., Rabbani, H., Mehridehnavi, A., & Hajizadeh, F. (2018). Macular OCT Classification Using a Multi-Scale Convolutional Neural Network Ensemble. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2017.2780115

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.