Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 189

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Pulmonary Artery–Vein Classification in CT Images Using Deep Learning

Open access
Nardelli, Pietro, Jimenez-Carretero, Daniel, Bermejo-Pelaez, David, Washko, George R., Rahaghi, Farbod N., Ledesma-Carbayo, Maria J., San Jose Estepar, Raul · 2018 · IEEE Transactions on Medical Imaging

Abstract

Recent studies show that pulmonary vascular diseases may specifically affect arteries or veins through different physiologic mechanisms. To detect changes in the two vascular trees, physicians manually analyze the chest computed tomography (CT) image of the patients in search of abnormalities. This process is time consuming, difficult to standardize, and thus not feasible for large clinical studies or useful in real-world clinical decision making. Therefore, automatic separation of arteries and veins in CT images is becoming of great interest, as it may help physicians to accurately diagnose pathological conditions. In this paper, we present a novel, fully automatic approach to classify vessels from chest CT images into arteries and veins. The algorithm follows three main steps: first, a scale-space particles segmentation to isolate vessels; then a 3-D convolutional neural network (CNN) to obtain a first classification of vessels; finally, graph-cuts' optimization to refine the results. To justify the usage of the proposed CNN architecture, we compared different 2-D and 3-D CNNs that may use local information from bronchus- and vessel-enhanced images provided to the network with different strategies. We also compared the proposed CNN approach with a random forests (RFs) classifier. The methodology was trained and evaluated on the superior and inferior lobes of the right lung of 18 clinical cases with noncontrast chest CT scans, in comparison with manual classification. The proposed algorithm achieves an overall accuracy of 94%, which is higher than the accuracy obtained using other CNN architectures and RF. Our method was also validated with contrast-enhanced CT scans of patients with chronic thromboembolic pulmonary hypertension to demonstrate that our model generalizes well to contrast-enhanced modalities. The proposed method outperforms state-of-the-art methods, paving the way for future use of 3-D CNN for artery/vein classification in CT images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2018.2833385

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 189

Metadata

Authors
Nardelli, P., Jimenez-Carretero, D., Bermejo-Pelaez, D., Washko, G. R., Rahaghi, F. N., Ledesma-Carbayo, M. J., & San Jose Estepar, R.
Venue
IEEE Transactions on Medical Imaging
Published
2018-11
Volume
37
Issue
11
Pages
2428-2440
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2800884849
Cited by
189
References
5
FWCI
9.60
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.