Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 534Advanced Neural Network ApplicationsMedical Image Segmentation TechniquesDomain Adaptation and Few-Shot Learning

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Recalibrating Fully Convolutional Networks With Spatial and Channel “Squeeze and Excitation” Blocks

Roy, Abhijit Guha, Navab, Nassir, Wachinger, Christian·2019·IEEE Transactions on Medical Imaging

Abstract

In a wide range of semantic segmentation tasks, fully convolutional neural networks (F-CNNs) have been successfully leveraged to achieve the state-of-the-art performance. Architectural innovations of F-CNNs have mainly been on improving spatial encoding or network connectivity to aid gradient flow. In this paper, we aim toward an alternate direction of recalibrating the learned feature maps adaptively, boosting meaningful features while suppressing weak ones. The recalibration is achieved by simple computational blocks that can be easily integrated in F-CNNs architectures. We draw our inspiration from the recently proposed "squeeze and excitation" (SE) modules for channel recalibration for image classification. Toward this end, we introduce three variants of SE modules for segmentation: 1) squeezing spatially and exciting channel wise; 2) squeezing channel wise and exciting spatially; and 3) joint spatial and channel SE. We effectively incorporate the proposed SE blocks in three state-of-the-art F-CNNs and demonstrate a consistent improvement of segmentation accuracy on three challenging benchmark datasets. Importantly, SE blocks only lead to a minimal increase in model complexity of about 1.5%, while the Dice score increases by 4%-9% in the case of U-Net. Hence, we believe that SE blocks can be an integral part of future F-CNN architectures.

Overview

Integrity signals

Registry

Crossref · 10.1109/tmi.2018.2867261

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 22 references

Research works printed but not linked: 1

  1. Landman, MICCAI 2012 workshop on multi-atlas labeling

Cited by

See all 534

Metadata

Authors
Roy, A. G., Navab, N., & Wachinger, C.
Affiliations
  • Technical University of Munich (DE)
  • Ludwig-Maximilians-Universität München (DE)
Venue
IEEE Transactions on Medical Imaging
Published
2019-02
Volume
38
Issue
2
Pages
540-549
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2888493720
Cited by
534
References
22
Citations by year
2026: 64 · 2025: 66 · 2024: 90 · 2023: 78 · 2022: 94 · 2021: 85 · 2020: 37 · 2019: 19
FWCI
17.76
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Medical Imaging (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Bavarian State Ministry of Education, Science
  • Arts in the Framework of the Centre Digitisation.Bavaria
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Computer Science › Artificial Intelligence › Domain Adaptation and Few-Shot Learning
Keywords
squeeze-and-excitation module, semantic segmentation, fully convolutional network, channel recalibration, U-Net, network architecture design, medical image segmentation
MeSH terms
Brain, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted, Retina, Databases, Factual, Neural Networks, Computer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recalibrating Fully Convolutional Networks With Spatial and Channel “Squeeze and Excitation” Blocks. https://app.cochat.ai/papers/10.1109/tmi.2018.2867261
The paper
Roy, A. G., Navab, N., & Wachinger, C. (2019). Recalibrating Fully Convolutional Networks With Spatial and Channel “Squeeze and Excitation” Blocks. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2018.2867261

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.