CoChat

A Universal Intensity Standardization Method Based on a Many-to-One Weak-Paired Cycle Generative Adversarial Network for Magnetic Resonance Images

Gao, Yuan, Liu, Yingchao, Wang, Yuanyuan, Shi, Zhifeng, Yu, Jinhua · 2019 · IEEE Transactions on Medical Imaging
Cited by 57

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

In magnetic resonance imaging (MRI), different imaging settings lead to various intensity distributions for a specific imaging object, which brings huge diversity to data-driven medical applications. To standardize the intensity distribution of magnetic resonance (MR) images from multiple centers and multiple machines using one model, a cycle generative adversarial network (CycleGAN)-based framework is proposed. It utilizes a unified forward generative adversarial network (GAN) path and multiple independent backward GAN paths to transform images in different groups into a single reference one. To preserve image details and prevent resolution loss, two jump connections are applied in the CycleGAN generators. A weak-pair strategy is designed to fully utilize the prior knowledge of the organ structure and promote the performance of the GANs. The experiments were conducted on a T2-FLAIR image database with 8192 slices from 489 patients. The database was obtained from four hospitals and five MRI scanners and was divided into nine groups with different imaging parameters. Compared with the representative algorithms, the peak signal-to-noise ratio, the histogram correlation, and the structural similarity were increased by 3.7%, 5.1%, and 0.1% on average, respectively; the gradient magnitude similarity deviation, the mean square error, and the average disparity were reduced by 19.0%, 15.7%, and 9.9% on average, respectively. Experiments also showed the robustness of the proposed model with a different training set configuration and effectiveness of the proposed framework over the original CycleGAN. Therefore, the MR images with different imaging settings could be efficiently standardized by the proposed method, which would benefit various data-driven applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2019.2894692

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 57

Metadata

Authors
Gao, Y., Liu, Y., Wang, Y., Shi, Z., & Yu, J.
Venue
IEEE Transactions on Medical Imaging
Published
2019-09
Volume
38
Issue
9
Pages
2059-2069
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2914765210
Cited by
57
References
5
FWCI
3.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Universal Intensity Standardization Method Based on a Many-to-One Weak-Paired Cycle Generative Adversarial Network for Magnetic Resonance Images. https://app.cochat.ai/papers/10.1109/tmi.2019.2894692
The paper
Gao, Y., Liu, Y., Wang, Y., Shi, Z., & Yu, J. (2019). A Universal Intensity Standardization Method Based on a Many-to-One Weak-Paired Cycle Generative Adversarial Network for Magnetic Resonance Images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2019.2894692

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.