CoChat

Detecting Deficient Coverage in Colonoscopies

Open access
Freedman, Daniel, Blau, Yochai, Katzir, Liran, Aides, Amit, Shimshoni, Ilan, Veikherman, Danny, Golany, Tomer, Gordon, Ariel, Corrado, Greg, Matias, Yossi, Rivlin, Ehud · 2020 · IEEE Transactions on Medical Imaging
Cited by 64

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Colonoscopy is tool of choice for preventing Colorectal Cancer, by detecting and removing polyps before they become cancerous. However, colonoscopy is hampered by the fact that endoscopists routinely miss 22-28% of polyps. While some of these missed polyps appear in the endoscopist's field of view, others are missed simply because of substandard coverage of the procedure, i.e. not all of the colon is seen. This paper attempts to rectify the problem of substandard coverage in colonoscopy through the introduction of the C2D2 (Colonoscopy Coverage Deficiency via Depth) algorithm which detects deficient coverage, and can thereby alert the endoscopist to revisit a given area. More specifically, C2D2 consists of two separate algorithms: the first performs depth estimation of the colon given an ordinary RGB video stream; while the second computes coverage given these depth estimates. Rather than compute coverage for the entire colon, our algorithm computes coverage locally, on a segment-by-segment basis; C2D2 can then indicate in real-time whether a particular area of the colon has suffered from deficient coverage, and if so the endoscopist can return to that area. Our coverage algorithm is the first such algorithm to be evaluated in a large-scale way; while our depth estimation technique is the first calibration-free unsupervised method applied to colonoscopies. The C2D2 algorithm achieves state of the art results in the detection of deficient coverage. On synthetic sequences with ground truth, it is 2.4 times more accurate than human experts; while on real sequences, C2D2 achieves a 93.0% agreement with experts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2020.2994221

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 64

Metadata

Authors
Freedman, D., Blau, Y., Katzir, L., Aides, A., Shimshoni, I., Veikherman, D., Golany, T., Gordon, A., Corrado, G., Matias, Y., & Rivlin, E.
Venue
IEEE Transactions on Medical Imaging
Published
2020-11
Volume
39
Issue
11
Pages
3451-3462
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W3002005236
Cited by
64
References
17
FWCI
3.77
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detecting Deficient Coverage in Colonoscopies. https://app.cochat.ai/papers/10.1109/tmi.2020.2994221
The paper
Freedman, D., Blau, Y., Katzir, L., Aides, A., Shimshoni, I., Veikherman, D., Golany, T., Gordon, A., Corrado, G., Matias, Y., & Rivlin, E. (2020). Detecting Deficient Coverage in Colonoscopies. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2020.2994221

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.