Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 597

The DOI matches its Crossref record; 108 of the 108 references it cites were found in a registry or an index.

ResViT: Residual Vision Transformers for Multimodal Medical Image Synthesis

Open access
Dalmaz, Onat, Yurt, Mahmut, Cukur, Tolga·2022·IEEE Transactions on Medical Imaging

Abstract

Generative adversarial models with convolutional neural network (CNN) backbones have recently been established as state-of-the-art in numerous medical image synthesis tasks. However, CNNs are designed to perform local processing with compact filters, and this inductive bias compromises learning of contextual features. Here, we propose a novel generative adversarial approach for medical image synthesis, ResViT, that leverages the contextual sensitivity of vision transformers along with the precision of convolution operators and realism of adversarial learning. ResViT's generator employs a central bottleneck comprising novel aggregated residual transformer (ART) blocks that synergistically combine residual convolutional and transformer modules. Residual connections in ART blocks promote diversity in captured representations, while a channel compression module distills task-relevant information. A weight sharing strategy is introduced among ART blocks to mitigate computational burden. A unified implementation is introduced to avoid the need to rebuild separate synthesis models for varying source-target modality configurations. Comprehensive demonstrations are performed for synthesizing missing sequences in multi-contrast MRI, and CT images from MRI. Our results indicate superiority of ResViT against competing CNN- and transformer-based methods in terms of qualitative observations and quantitative metrics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2022.3167808

Cites

108 of 108 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 108 references

Cited by

See all 597

Metadata

Authors
Dalmaz, O., Yurt, M., & Cukur, T.
Venue
IEEE Transactions on Medical Imaging
Published
2022-10
Volume
41
Issue
10
Pages
2598-2614
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W3176466780
Cited by
597
References
108
FWCI
39.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ResViT: Residual Vision Transformers for Multimodal Medical Image Synthesis. https://app.cochat.ai/papers/10.1109/tmi.2022.3167808
The paper
Dalmaz, O., Yurt, M., & Cukur, T. (2022). ResViT: Residual Vision Transformers for Multimodal Medical Image Synthesis. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2022.3167808

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.