CoChat

HoVer-Trans: Anatomy-Aware HoVer-Transformer for ROI-Free Breast Cancer Diagnosis in Ultrasound Images

Open access
Mo, Yuhao, Han, Chu, Liu, Yu, Liu, Min, Shi, Zhenwei, Lin, Jiatai, Zhao, Bingchao, Huang, Chunwang, Qiu, Bingjiang, Cui, Yanfen, Wu, Lei, Pan, Xipeng, Xu, Zeyan, Huang, Xiaomei, Li, Zhenhui, Liu, Zaiyi, Wang, Ying, Liang, Changhong · 2023 · IEEE Transactions on Medical Imaging
Cited by 162

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

Ultrasonography is an important routine examination for breast cancer diagnosis, due to its non-invasive, radiation-free and low-cost properties. However, the diagnostic accuracy of breast cancer is still limited due to its inherent limitations. Then, a precise diagnose using breast ultrasound (BUS) image would be significant useful. Many learning-based computer-aided diagnostic methods have been proposed to achieve breast cancer diagnosis/lesion classification. However, most of them require a pre-define region of interest (ROI) and then classify the lesion inside the ROI. Conventional classification backbones, such as VGG16 and ResNet50, can achieve promising classification results with no ROI requirement. But these models lack interpretability, thus restricting their use in clinical practice. In this study, we propose a novel ROI-free model for breast cancer diagnosis in ultrasound images with interpretable feature representations. We leverage the anatomical prior knowledge that malignant and benign tumors have different spatial relationships between different tissue layers, and propose a HoVer-Transformer to formulate this prior knowledge. The proposed HoVer-Trans block extracts the inter- and intra-layer spatial information horizontally and vertically. We conduct and release an open dataset GDPH&SYSUCC for breast cancer diagnosis in BUS. The proposed model is evaluated in three datasets by comparing with four CNN-based models and three vision transformer models via five-fold cross validation. It achieves state-of-the-art classification performance (GDPH&SYSUCC AUC: 0.924, ACC: 0.893, Spec: 0.836, Sens: 0.926) with the best model interpretability. In the meanwhile, our proposed model outperforms two senior sonographers on the breast cancer diagnosis when only one BUS image is given (GDPH&SYSUCC-AUC ours: 0.924 vs. reader1: 0.825 vs. reader2: 0.820).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2023.3236011

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Metadata

Authors
Mo, Y., Han, C., Liu, Y., Liu, M., Shi, Z., Lin, J., Zhao, B., Huang, C., Qiu, B., Cui, Y., Wu, L., Pan, X., Xu, Z., Huang, X., Li, Z., Liu, Z., Wang, Y., & Liang, C.
Venue
IEEE Transactions on Medical Imaging
Published
2023-06
Volume
42
Issue
6
Pages
1696-1706
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W4315630813
Cited by
162
References
42
FWCI
14.06
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: HoVer-Trans: Anatomy-Aware HoVer-Transformer for ROI-Free Breast Cancer Diagnosis in Ultrasound Images. https://app.cochat.ai/papers/10.1109/tmi.2023.3236011
The paper
Mo, Y., Han, C., Liu, Y., Liu, M., Shi, Z., Lin, J., Zhao, B., Huang, C., Qiu, B., Cui, Y., Wu, L., Pan, X., Xu, Z., Huang, X., Li, Z., Liu, Z., Wang, Y., & Liang, C. (2023). HoVer-Trans: Anatomy-Aware HoVer-Transformer for ROI-Free Breast Cancer Diagnosis in Ultrasound Images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2023.3236011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.