The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Optical-to-Tactile Image Conversion for the Blind
Abstract
This paper describes two optical-to-tactile imageconversion systems being developed for the blind. The first is a reading aid in which an area on the printed page about the size of a letterspace is translated into a corresponding vibratory tactile image. The tactile image is produced by a 24-by-6 array of pins driven by piezoelectric bimorphs. The array of 144 pins fits on the distal and a portion of the middle phalanges of one finger. The piezoelectric bimorphs cause the pins to impact the skin in a nonlinear manner. Precise measurements on this bimorph-finger system are given. These measurements also show that shades of "grey" can be displayed by sequentially varying the threshold level. Three experiments conducted with the reading aid involved measurement of legibility, reading rate, and the effect of field of view. Legibility in the 92-98 percent range was obtained at the design magnification. A reading rate of 50 words per minute was achieved with one subject after roughly 160 hours of practice. Three other subjects achieved reading rates of over 10 words per minute after about 40 hours of practice. Reading rate increased markedly as the number of columns in the array was varied from one to six. The second optical-to-tactile image-conversion system is merely an extension of the first to permit information to be acquired from the environment. In fact, ultimately only one system with two sets of optics, one appropriate for the printed page and one appropriate for environment sensing, would be used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A direct translation reading aid for the blind
Linvill, J. G., & Bliss, J. C. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4572 · Cited by 218
Self-citationA Relatively High-Resolution Reading Aid for the Blind
Bliss, J. C. (1969) · IEEE Transactions on Man Machine Systems · doi:10.1109/tmms.1969.299874 · Cited by 69
Self-citationIntegrated Electronics for a Reading Aid for the Blind
Brugler, J. S., MEINDL, J. D., Plummer, J. D., et al. (1969) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1969.1050028 · Cited by 31
Cited by
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Tactile Displays: Guidance for Their Design and Application
Jones, L. A., & Sarter, N. B. (2008) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872008x250638 · Cited by 561
Touch is a team effort: interplay of submodalities in cutaneous sensibility
Saal, H. P., & Bensmaia, S. J. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2014.08.012 · Cited by 280
Tactile Display of Vibratory Information in Teleoperation and Virtual Environments
Kontarinis, D. A., & Howe, R. D. (1995) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1995.4.4.387 · Cited by 251
Csapó, Á., Wersényi, G., Nagy, H., & Stockman, T. (2015) · Journal on Multimodal User Interfaces · doi:10.1007/s12193-015-0182-7 · Cited by 181
Metadata
- Authors
- Bliss, J., Katcher, M., Rogers, C., & Shepard, R.
- Venue
- IEEE Transactions on Man Machine Systems
- Published
- 1970-03
- Volume
- 11
- Issue
- 1
- Pages
- 58-65
- ISSN
- 0536-1540 (ISSN-L)
- OpenAlex
- W1994319062
- Cited by
- 306
- References
- 3
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical-to-Tactile Image Conversion for the Blind. https://app.cochat.ai/papers/10.1109/tmms.1970.299963
- The paper
- Bliss, J., Katcher, M., Rogers, C., & Shepard, R. (1970). Optical-to-Tactile Image Conversion for the Blind. IEEE Transactions on Man Machine Systems. https://doi.org/10.1109/tmms.1970.299963
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.