Numerical and Experimental Millimeter-Wave Dosimetry for In Vitro Experiments
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper provides extensive dosimetry data forinvitroexperiments regarding the biological effects of millimeter waves. Two particular frequency ranges have been considered, which are: (1) the 57-64-GHz frequency range dedicated to near-future applications in high-speed wireless communication systems and (2) the discrete frequencies used in millimeter-wave therapy, namely, 42.25, 53.57, and 61.22 GHz. The dielectric properties of keratinocyte cells and culture media were determined using permittivity data of free water and Maxwell's mixture equation. The local specific absorption rate (SAR) distribution within the cell monolayer located in a standard tissue culture plate was computed using the finite-element method and the finite-integration technique. The averaged near-surface SAR for the cell monolayer was determined using both numerical electric-field-based and experimental temperature-based approaches. The SAR was computed taking into account physiological variations of the water content in the keratinocyte cells, as well as variations in the cell monolayer thickness. Experimental and computational results are shown to be in very good agreement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhadobov, M., Sauleau, R., Le Coq, L., Debure, L., Thouroude, D., Michel, D., & Le Dréan, Y. (2007) · Bioelectromagnetics · doi:10.1002/bem.20285 · Cited by 38 · cited 1×
“Experimental laboratory and clinical investigations of biological effects of millimeter waves have used both in vitro and in vivo approaches [3], [5]–[8].”
MethodSelf-citation
Cited by
Evaluation of the Potential Biological Effects of the 60-GHz Millimeter Waves Upon Human Cells
Zhadobov, M., Nicolaz, C. N., Sauleau, R., Desmots, F., Thouroude, D., Michel, D., & Le Drean, Y. (2009) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2009.2029308 · Cited by 53
“The corresponding data are available in [27] from 30 to 100 GHz.”
BackgroundMethodInfluentialSelf-citationNicolaz, C. N., Zhadobov, M., Desmots, F., Ansart, A., Sauleau, R., Thouroude, D., Michel, D., & Drean, Y. L. (2009) · Bioelectromagnetics · doi:10.1002/bem.20481 · Cited by 24
“Dielectric properties and conductivity data for the cells, culture medium, and polystyrene were taken from a previous study [Zhadobov et al., 2008].”
MethodInfluentialSelf-citationNicolas Nicolaz, C., Zhadobov, M., Desmots, F., Sauleau, R., Thouroude, D., Michel, D., & Le Drean, Y. (2009) · Cell Biology and Toxicology · doi:10.1007/s10565-008-9101-y · Cited by 24
Self-citation
Metadata
- Authors
- Zhadobov, M., Sauleau, R., Le Drean, Y., Alekseev, S. I., & Ziskin, M. C.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2008-12
- Volume
- 56
- Issue
- 12
- Pages
- 2998-3007
- ISSN
- 0018-9480 (ISSN-L)
- 1557-9670
- OpenAlex
- W2144858246
- Cited by
- 41
- References
- 1
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Numerical and Experimental Millimeter-Wave Dosimetry for In Vitro Experiments. https://app.cochat.ai/papers/10.1109/tmtt.2008.2006797
- The paper
- Zhadobov, M., Sauleau, R., Le Drean, Y., Alekseev, S. I., & Ziskin, M. C. (2008). Numerical and Experimental Millimeter-Wave Dosimetry for In Vitro Experiments. IEEE Transactions on Microwave Theory and Techniques. https://doi.org/10.1109/tmtt.2008.2006797
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.