Performance Study of PETT VI, a Positron Computed Tomograph with 288 Cesium Fluoride Detectors
The DOI matches its Crossref record.
Abstract
The first positron computed tomography system with cesium fluoride scintillation detectors, PETT VI, has been developed. The system provides 7 slice images with 4 detector rings (57 cm). Performances of the system are discussed and clarified based on experimental data. Adoption of CsF detectors decrease the random coincidence rate by achieving a short coincidence timing resolution. The timing resolution of a pair of detector heads is 1.5 nsec FWHM and 3.0 nsec FWTM. After a preliminary timing alignment of 288 detectors, the coincidence window width (2τ) of 11 nsec or wiider has yielded maximum coincidence sensitivity, and operation at 5.9 nsec has given 91% of maximum. The full sensitivity for a cyclindrical uniform phantom (20 cm dia × 13 cm) is 354 kcps/microCi/cc/7 slices in a low resolution mode (intrinsic resolution at center is 11.7 mm FWHM). In a high resolution mode (7.1 mm), it is 31% of the full sensitivity. Coincidence rates ratio, [random/(true + scattered)], in the low resolution mode, is 0.16 α with 5.9 nsec window width inside the phantom images reconstructed without a random correction, where α is activity density (microCi/cc). The ratio is 1/3 of that obtained when operating at 20 nsec. Scattered coincidence fraction at the center of the phantom images, without the random correction process, is 9% of the [true + scattered].
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A default mode of brain function
Raichle, M. E., MacLeod, A. M., Snyder, A. Z., Powers, W. J., Gusnard, D. A., & Shulman, G. L. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.2.676 · Cited by 12,190
Practice-related Changes in Human Brain Functional Anatomy during Nonmotor Learning
Raichle, M. E., Fiez, J. A., Videen, T. O., MacLeod, A.-M. K., Pardo, J. V., Fox, P. T., & Petersen, S. E. (1994) · Cerebral Cortex · doi:10.1093/cercor/4.1.8 · Cited by 1,593
Corbetta, M., Miezin, F., Dobmeyer, S., Shulman, G., & Petersen, S. (1991) · The Journal of Neuroscience · doi:10.1523/jneurosci.11-08-02383.1991 · Cited by 1,588
A PET study of visuospatial attention
Corbetta, M., Miezin, F., Shulman, G., & Petersen, S. (1993) · The Journal of Neuroscience · doi:10.1523/jneurosci.13-03-01202.1993 · Cited by 1,520
Localization of a human system for sustained attention by positron emission tomography
Pardo, J. V., Fox, P. T., & Raichle, M. E. (1991) · Nature · doi:10.1038/349061a0 · Cited by 1,284
Metadata
- Authors
- Yamamoto, M., Ficke, D. C., & Ter-Pogossian, M. M.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 1982-02
- Volume
- 29
- Issue
- 1
- Pages
- 529-533
- ISSN
- 0018-9499 (ISSN-L)
- 1558-1578
- OpenAlex
- W2039543916
- Cited by
- 79
- References
- 0
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance Study of PETT VI, a Positron Computed Tomograph with 288 Cesium Fluoride Detectors. https://app.cochat.ai/papers/10.1109/tns.1982.4335901
- The paper
- Yamamoto, M., Ficke, D. C., & Ter-Pogossian, M. M. (1982). Performance Study of PETT VI, a Positron Computed Tomograph with 288 Cesium Fluoride Detectors. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/tns.1982.4335901
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.