The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays
Abstract
High-resolution three-dimensional (3-D) positron emission tomography (PET) scanners with high count rate performance, such as the quad-high density avalanche chamber (HIDAC), place new demands on image reconstruction algorithms due to the large quantities of high-precision list-mode data which are produced. Therefore, a reconstruction algorithm is required which can, in a practical time frame, reconstruct into very large image arrays (submillimeter voxels, which range over a large field of view) whilst preferably retaining the precision of the data. This work presents an algorithm which meets these demands: one-pass list-mode expectation maximization (OPL-EM) algorithm. The algorithm operates directly on list-mode data, passes through the data once only, accounts for finite resolution effects in the system model, and can also include regularization. The algorithm performs multiple image updates during its single pass through the list-mode data, corresponding to the number of subsets that the data have been split into. The algorithm has been assessed using list-mode data from a quad-HIDAC and is compared to the analytic reconstruction method 3-D reprojection (RP) with 3-D filtered backprojection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Cited by
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
Iterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls
Rahmim, A., Qi, J., & Sossi, V. (2013) · Medical Physics · doi:10.1118/1.4800806 · Cited by 357
In vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
History and future technical innovation in positron emission tomography
Jones, T., & Townsend, D. (2017) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.1.011013 · Cited by 303
Metadata
- Authors
- Reader, A. J., Ally, S., Bakatselos, F., Manavaki, R., Walledge, R. J., Jeavons, A. P., Julyan, P. J., Zhao, S., Hastings, D. L., & Zweit, J.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 2002-06
- Volume
- 49
- Issue
- 3
- Pages
- 693-699
- ISSN
- 0018-9499 (ISSN-L)
- 1558-1578
- OpenAlex
- W2105282068
- Cited by
- 232
- References
- 1
- FWCI
- 9.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays. https://app.cochat.ai/papers/10.1109/tns.2002.1039550
- The paper
- Reader, A. J., Ally, S., Bakatselos, F., Manavaki, R., Walledge, R. J., Jeavons, A. P., Julyan, P. J., Zhao, S., Hastings, D. L., & Zweit, J. (2002). One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/tns.2002.1039550
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.