The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
High-resolution SPECT using multipinhole collimation
Abstract
The authors present a novel SPECT imaging technique for small animal research based on multipinhole collimation. This new method is an extension of single-pinhole tomography and combines high resolution with increased system sensitivity. This paper describes the multipinhole imaging system and its preliminary characterization on simulated and measured phantom data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals.
Weber, D. A., Ivanović, M., Franceschi, D., et al. (1994) · PubMed · Cited by 223
Ultra-high resolution SPECT system using four pinhole collimators for small animal studies.
Ishizu, K., Mukai, T., Yonekura, Y., et al. (1995) · PubMed · Cited by 205
A prototype coded aperture detector for small animal SPECT
Meikle, S. R., Kench, P. L., Weisenberger, A. G., Wojcik, R. F., Smith, M. F., Majewski, S., Eberl, S., Fulton, R., Rosenfeld, A. B., & FULHAM, M. J. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.803802 · Cited by 122
Reconstruction of two- and three-dimensional images from synthetic-collimator data
Wilson, D. W., Barrett, H. H., & Clarkson, E. W. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.870252 · Cited by 58
Cited by
Dewaraja, Y. K., Frey, E. C., Sgouros, G., Brill, A. B., Roberson, P., Zanzonico, P. B., & Ljungberg, M. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.100123 · Cited by 419
Jong, H. W. A. M. D., Velden, F. H. P. V., Kloet, R. W., Buijs, F. L., Boellaard, R., & Lammertsma, A. A. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/5/019 · Cited by 349
Recent Advances in SPECT Imaging
Madsen, M. T. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.032680 · Cited by 338
Metadata
- Authors
- Schramm, N. U., Ebel, G., Engeland, U., Schurrat, T., Behe, M., & Behr, T. M.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 2003-06
- Volume
- 50
- Issue
- 3
- Pages
- 315-320
- ISSN
- 0018-9499 (ISSN-L)
- 1558-1578
- OpenAlex
- W2160203786
- Cited by
- 298
- References
- 6
- FWCI
- 20.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-resolution SPECT using multipinhole collimation. https://app.cochat.ai/papers/10.1109/tns.2003.812437
- The paper
- Schramm, N. U., Ebel, G., Engeland, U., Schurrat, T., Behe, M., & Behr, T. M. (2003). High-resolution SPECT using multipinhole collimation. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/tns.2003.812437
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.