The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
What does the eye tell the brain?: Development of a system for the large-scale recording of retinal output activity
Abstract
A multielectrode array system has been developed to study how the retina processes and encodes visual images. This system can simultaneously record the extracellular electrical activity from hundreds of retinal output neurons as a dynamic visual image is focused on the input neurons. The retinal output signals detected can be correlated with the visual input to study the neural code used by the eye to send information about the visual world to the brain. The system consists of the following components: 1) a 32 /spl times/ 16 rectangular array of 512 planar microelectrodes with a sensitive area of 1.7 mm/sup 2/; the electrode spacing is 60 /spl mu/m and the electrode diameter is 5 /spl mu/m (hexagonal arrays with 519 electrodes are under development); 2) eight 64-channel custom-designed integrated circuits to platinize the electrodes and ac couple the signals; 3) eight 64-channel integrated circuits to amplify, band-pass filter, and analog multiplex the signals; 4) a data acquisition system; and 5) data processing software. This paper will describe the design of the system, the experimental and data analysis techniques, and some first results with live retina. The system is based on techniques and expertise acquired in the development of silicon microstrip detectors for high-energy physics experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A simple white noise analysis of neuronal light responses
Chichilnisky, E. J. (2001) · Network Computation in Neural Systems · doi:10.1080/net.12.2.199.213 · Cited by 770
Self-citationA simple white noise analysis of neuronal light responses
Chichilnisky, E. J. (2001) · Network: Computation in Neural Systems · doi:10.1080/713663221 · Cited by 670
Self-citationMulti-neuronal signals from the retina: acquisition and analysis
Meister, M., Pine, J., & Baylor, D. A. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90030-2 · Cited by 411
Large-area microelectrode arrays for recording of neural signals
Mathieson, K., Kachiguine, S., Adams, C., et al. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.835873 · Cited by 47
Self-citationThe retinal readout system: an application of microstrip detector technology to neurobiology
Litke, A. M. (1998) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(98)00734-7 · Cited by 19
Self-citationThe Retinal Readout System: a status report
Litke, A. M. (1999) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(99)00445-3 · Cited by 18
Self-citationDąbrowski, W., Gryboś, P., Hottowy, P., et al. (2003) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2003.1351853 · Cited by 12
Self-citation
Cited by
Spatio-temporal correlations and visual signalling in a complete neuronal population
Pillow, J. W., Shlens, J., Paninski, L., Sher, A., Litke, A. M., Chichilnisky, E. J., & Simoncelli, E. P. (2008) · Nature · doi:10.1038/nature07140 · Cited by 1,311
Self-citationAre Biological Systems Poised at Criticality?
Mora, T., & Bialek, W. (2011) · Journal of Statistical Physics · doi:10.1007/s10955-011-0229-4 · Cited by 734
“Such experiments routinely allow measurements on ∼ 100 neurons, in some cases sampling densely from a small region of the retina, so that this represents a significant fraction of all the cells in the area covered by the electrode array [10, 11].”
BackgroundMethodRevealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
Jacobs, A. (2009) · Communications of the ACM · doi:10.1145/1536616.1536632 · Cited by 643
The Structure of Multi-Neuron Firing Patterns in Primate Retina
Shlens, J., Field, G. D., Gauthier, J. L., Grivich, M. I., Petrusca, D., Sher, A., Litke, A. M., & Chichilnisky, E. J. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.1282-06.2006 · Cited by 468
Self-citation
Metadata
- Authors
- Litke, A. M., Bezayiff, N., Chichilnisky, E. J., Cunningham, W., Dabrowski, W., Grillo, A. A., Grivich, M., Grybos, P., Hottowy, P., Kachiguine, S., Kalmar, R. S., Mathieson, K., Petrusca, D., Rahman, M., & Sher, A.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 2004-08
- Volume
- 51
- Issue
- 4
- Pages
- 1434-1440
- ISSN
- 0018-9499 (ISSN-L)
- OpenAlex
- W2117018945
- Cited by
- 279
- References
- 7
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.