The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware
Abstract
The task of reconstructing an object from its projections via tomographic methods is a time-consuming process due to the vast complexity of the data. For this reason, manufacturers of equipment for medical computed tomography (CT) rely mostly on special application specified integrated circuits (ASICs) to obtain the fast reconstruction times required in clinical settings. Although modern CPUs have gained sufficient power in recent years to be competitive for two-dimensional (2D) reconstruction, this is not the case for three-dimensional (3D) reconstructions, especially not when iterative algorithms must be applied. The recent evolution of commodity PC computer graphics boards (GPUs) has the potential to change this picture in a very dramatic way. In this paper we will show how the new floating point GPUs can be exploited to perform both analytical and iterative reconstruction from X-ray and functional imaging data. For this purpose, we decompose three popular three-dimensional (3D) reconstruction algorithms (Feldkamp filtered backprojection, the simultaneous algebraic reconstruction technique, and expectation maximization) into a common set of base modules, which all can be executed on the GPU and their output linked internally. Visualization of the reconstructed object is easily achieved since the object already resides in the graphics hardware, allowing one to run a visualization module at any time to view the reconstruction results. Our implementation allows speedups of over an order of magnitude with respect to CPU implementations, at comparable image quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Cited by
A Survey of General‐Purpose Computation on Graphics Hardware
Owens, J. D., Luebke, D., Govindaraju, N., Harris, M., Krüger, J., Lefohn, A. E., & Purcell, T. J. (2007) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2007.01012.x · Cited by 2,101
Wildenschild, D., & Sheppard, A. P. (2013) · Advances in Water Resources · doi:10.1016/j.advwatres.2012.07.018 · Cited by 1,239
A review on CT image noise and its denoising
Diwakar, M., & Kumar, M. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.01.010 · Cited by 416
Medical image processing on the GPU – Past, present and future
Eklund, A., Dufort, P., Forsberg, D., & LaConte, S. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.008 · Cited by 397
Low-dose CT reconstruction via edge-preserving total variation regularization
Tian, Z., Jia, X., Yuan, K., Pan, T., & Jiang, S. B. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/18/011 · Cited by 396
Metadata
- Authors
- Xu, F., & Mueller, K.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 2005-06
- Volume
- 52
- Issue
- 3
- Pages
- 654-663
- ISSN
- 0018-9499 (ISSN-L)
- OpenAlex
- W2116669464
- Cited by
- 252
- References
- 1
- FWCI
- 13.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware. https://app.cochat.ai/papers/10.1109/tns.2005.851398
- The paper
- Xu, F., & Mueller, K. (2005). Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/tns.2005.851398
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.