Performance Evaluation of the microPET®—FOCUS-F120
The DOI matches its Crossref record.
Abstract
microPETreg-Focus-F120 is the latest model of dedicated small animal PET scanners from CTI-Concorde Microsystems LLC, (Knoxville, TN). This scanner, based on the geometry of the microPET-R4, takes advantage of several detector modifications to the coincidence processing electronics that improve the image resolution, sensitivity, and counting rate performance as compared to the predecessor models. This work evaluates the performance of the Focus-F120 system and shows its improvement over the earlier models. In particular, the spatial resolution is shown to improve from 2.32 to 1.69 mm at 5 mm radial distance and the peak absolute sensitivity increases from 4.1% to 7.1% compared to the microPET-R4. The counting rate capability, expressed in noise equivalent counting rate (NEC-1R), was shown to peak at over 800 kcps at 88 MBq for both systems using a mouse phantom. For this small phantom, the NECR counting rate is limited by the data transmission bandwidth between the scanner and the acquisition console. The rat-like phantom showed peak NEC-1R value at 300 kcps at 140 MBq. Evaluation of image quality and quantitation accuracy was also performed using specially designed phantoms and animal experiments
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bao, Q., Newport, D., Chen, M., Stout, D. B., & Chatziioannou, A. F. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056374 · Cited by 306
Self-citationPET-MRI: a review of challenges and solutions in the development of integrated multimodality imaging
Vandenberghe, S., & Marsden, P. K. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/4/r115 · Cited by 258
Lehnert, W., Gregoire, M.-C., Reilhac, A., & Meikle, S. R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.032 · Cited by 52
Quantitative Receptor-Based Imaging of Tumor Proliferation with the Sigma-2 Ligand [18F]ISO-1
Shoghi, K. I., Xu, J., Su, Y., He, J., Rowland, D., Yan, Y., Garbow, J. R., Tu, Z., Jones, L. A., Higashikubo, R., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0074188 · Cited by 44
Preclinical radiation dosimetry for the novel SV2A radiotracer [18F]UCB-H
Bretin, F., Warnock, G., Bahri, M. A., Aerts, J., Mestdagh, N., Buchanan, T., Valade, A., Mievis, F., Giacomelli, F., Lemaire, C., et al. (2013) · EJNMMI Research · doi:10.1186/2191-219x-3-35 · Cited by 43
Metadata
- Authors
- Laforest, R., Longford, D., Siegel, S., Newport, D. F., & Yap, J.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 2007-02
- Volume
- 54
- Issue
- 1
- Pages
- 42-49
- ISSN
- 0018-9499 (ISSN-L)
- OpenAlex
- W2174242760
- Cited by
- 93
- References
- 0
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance Evaluation of the microPET®—FOCUS-F120. https://app.cochat.ai/papers/10.1109/tns.2006.889312
- The paper
- Laforest, R., Longford, D., Siegel, S., Newport, D. F., & Yap, J. (2007). Performance Evaluation of the microPET®—FOCUS-F120. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/tns.2006.889312
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.