Prevention of muscle disuse atrophy by low-frequency electrical stimulation in rats
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
When muscles lose neural drive, they atrophy rapidly. Neuromuscular electrical stimulation (NMS) has been used in attempts to prevent or reverse the atrophy, but optimal stimulation programs and parameters are not well defined. In this study, we investigated the effects of four different stimulation patterns on disuse atrophy produced in the tibialis anterior, lateral gastrocnemius, and soleus muscles of rats paralyzed with tetrodotoxin for seven days. Stimulation paradigms differed from one another by their stimulation frequency (2 or 10 pulses/s) and by their stimulation period (2 or 10 h a day). Results showed that stimulation with 2 pulses/s, paradigms were more effective at preventing disuse muscle atrophy than higher-frequency stimulation. The most marked difference was in the slow soleus muscle, which had only 10% mean atrophy when stimulated at 2 pulses/s for 10 h, compared to 26% atrophy when stimulated at 10 pulses/s for either 2 or 10 h and 32% atrophy in unstimulated, paralyzed controls. The level of atrophic change was not correlated with the levels of serum creatine kinase, used as an index of muscle damage. Results suggest that remediation of disuse atrophy may be accomplished using unphysiologically low rates of motor-unit activation despite the relatively low force produced by such unfused contractions. This may have significant implications for the design of therapies for muscle paralysis consequent to upper-motoneuron lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-term biocompatibility of a miniature stimulator implanted in feline hind limb muscles
Cameron, T., Liinamaa, T. L., Loeb, G. E., & Richmond, F. J. R. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.704871 · Cited by 53
Self-citation
Cited by
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
Nanogenerators for smart cities in the era of 5G and Internet of Things
Zhao, X., Askari, H., & Chen, J. (2021) · Joule · doi:10.1016/j.joule.2021.03.013 · Cited by 436
Alterations of protein turnover underlying disuse atrophy in human skeletal muscle
Phillips, S. M., Glover, E. I., & Rennie, M. J. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00452.2009 · Cited by 322
“7% · d in slow fiber dominated 118 muscles (usually soleus) (15, 36, 55, 61, 70, 93, 104, 133).”
Guo, B.-S., Cheung, K.-K., Yeung, S. S., Zhang, B.-T., & Yeung, E. W. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030348 · Cited by 105
Metadata
- Authors
- Dupont Salter, A. C., Richmond, F. J. R., & Loeb, G. E.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2003-09
- Volume
- 11
- Issue
- 3
- Pages
- 218-226
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2163802391
- Cited by
- 54
- References
- 1
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prevention of muscle disuse atrophy by low-frequency electrical stimulation in rats. https://app.cochat.ai/papers/10.1109/tnsre.2003.817674
- The paper
- Dupont Salter, A. C., Richmond, F. J. R., & Loeb, G. E. (2003). Prevention of muscle disuse atrophy by low-frequency electrical stimulation in rats. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2003.817674
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.