CoChat

A Novel Mechatronic Body Weight Support System

Frey, M., Colombo, G., Vaglio, M., Bucher, R., Jorg, M., Riener, R. · 2006 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 204

The DOI matches its Crossref record.

Abstract

A novel mechatronic body weight support (BWS) system has been developed to provide precise body weight unloading for patients with neurological or other impairments during treadmill training. The system is composed of a passive elastic spring element to take over the main unloading force and an active closed-loop controlled electric drive to generate the exact desired force. Both force generating units, the passive spring and the active electric drive, act on the patient via a polyester rope connected to a harness worn by the patient. The length of the rope can be adjusted with an electric winch to adapt the system to different patient sizes. The system is fully computer controlled. At unloading loads of up to 60 kg and walking speeds of up to 3.2 km/h, the mean unloading error and the maximum unloading error of the presented BWS system was less than 1 and 3 kg, respectively. The performance was compared with those of two purely passive BWS systems currently being used by most other rehabilitation groups. This comprised counterweight systems and static BWS systems with fixed rope lengths. Counterweight systems reached mean and maximum unloading errors of up to 5.34 and 16.22 kg, respectively. The values for the static BWS were 11.02 kg and 27.67 kg, respectively. The novel mechatronic BWS system presented in this study adjusts desired unloading changes of up to 20 kg within less than 100 ms. Thus, not only constant BWS, but also gait cycle dependent or time variant oscillations of the desired force can be realized with high accuracy. Precise and constant unloading force is believed to be an important prerequisite for BWS gait therapy, where it is important to generate physiologically correct segmental dynamics and ground reaction forces. Thus, the novel BWS system presented in this paper is an important contribution to maximize the therapeutic outcome of human gait rehabilitation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2006.881556

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Frey, M., Colombo, G., Vaglio, M., Bucher, R., Jorg, M., & Riener, R.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2006-09
Volume
14
Issue
3
Pages
311-321
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2131687889
Cited by
204
References
0
FWCI
9.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Mechatronic Body Weight Support System. https://app.cochat.ai/papers/10.1109/tnsre.2006.881556
The paper
Frey, M., Colombo, G., Vaglio, M., Bucher, R., Jorg, M., & Riener, R. (2006). A Novel Mechatronic Body Weight Support System. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2006.881556

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.