The DOI matches its Crossref record.
Hand Spring Operated Movement Enhancer (HandSOME): A Portable, Passive Hand Exoskeleton for Stroke Rehabilitation
Abstract
Stroke patients often have flexor hypertonia and finger extensor weakness, which makes it difficult to open their affected hand for functional grasp. Because of this impairment, hand rehabilitation after stroke is essential for restoring functional independent lifestyles. The goal of this study is to develop a passive, lightweight, wearable device to assist with hand function during performance of activities of daily living. The device, Hand Spring Operated Movement Enhancer (HandSOME), assists with opening the patient's hand using a series of elastic cords that apply extension torques to the finger joints and compensates for the flexor hypertonia. Device design and calibration are described as well as functional and usability testing with stroke subjects with a wide range of hand impairments. In initial testing with eight stroke subjects with finger flexor hypertonia, use of the HandSOME significantly increased range of motion and functional ability (p=0.002) . There was some decrease in grip strength with the HandSOME device at the subject's ideal setting, however this was not statistically significant (p=0.167) and did not seem to have a significant effect on function. Overall HandSOME shows promise as a training tool to facilitate repetitive task practice for improving hand function in stroke patients. HandSOME can be used as part of a home-based therapy program, or as an orthotic for replacing lost function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
Current hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
Metadata
- Authors
- Brokaw, E. B., Black, I., Holley, R. J., & Lum, P. S.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-08
- Volume
- 19
- Issue
- 4
- Pages
- 391-399
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2106818390
- Cited by
- 197
- References
- 0
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hand Spring Operated Movement Enhancer (HandSOME): A Portable, Passive Hand Exoskeleton for Stroke Rehabilitation. https://app.cochat.ai/papers/10.1109/tnsre.2011.2157705
- The paper
- Brokaw, E. B., Black, I., Holley, R. J., & Lum, P. S. (2011). Hand Spring Operated Movement Enhancer (HandSOME): A Portable, Passive Hand Exoskeleton for Stroke Rehabilitation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2011.2157705
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.