Experimental Validation of a Hybrid Computational Model for Selective Stimulation Using Transverse Intrafascicular Multichannel Electrodes
Open accessAbstract
Recently a hybrid model based on the finite element method and on a compartmental biophysical representation of peripheral nerve fibers and intraneural electrodes was developed founded on experimental physiological and histological data. The model appeared to be robust when dealing with uncertainties in parameter selection. However, an experimental validation of the findings provided by the model is required to fully characterize the potential of this approach. The recruitment properties of selective nerve stimulation using transverse intrafascicular multichannel electrodes (TIME) were investigated in this work in experiments with rats and were compared to model predictions. Animal experiments were performed using the same stimulation protocol as in the computer simulations in order to rigorously validate the model predictions and understand its limitations. Two different selectivity indexes were used, and new indexes for measuring electrode performance are proposed. The model predictions are in decent agreement with experimental results both in terms of recruitment curves and selectivity values. Results show that these models can be used for extensive studies targeting electrode shape design, active sites shape, and multipolar stimulation paradigms. From a neurophysiological point of view, the topographic organization of the rat sciatic nerve, on which the model was based, has been confirmed.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Selectively recruiting different layers in the peripheral nerve results in a graded force generation in various muscle groups.
“For instance, selectively recruiting different layers in the peripheral nerve results in a graded force generation in various muscle groups23–25.”
From A flexible three-dimensional electrode mesh: An enabling technology for wireless brain–computer interface prostheses (2016) · cites this paper as [25]
The citation lists haven’t been fetched yet
References 40 · Cited by 63
- Authors
- Raspopovic, S., Capogrosso, M., Badia, J., Navarro, X., & Micera, S.
- Affiliations
- Scuola Superiore Sant'Anna (IT)
- Universitat Autònoma de Barcelona (ES)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2012-05
- Volume
- 20
- Issue
- 3
- Pages
- 395-404
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2136104363
- Semantic Scholar
- bf5cd59f395c1a656f94cc7d8a983084187fe8b4
- Cited by
- 63
- References
- 40
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 4 · 2023: 8 · 2022: 4 · 2021: 7 · 2020: 4 · 2019: 3 · 2018: 2 · 2017: 4 · 2016: 5 · 2015: 9 · 2014: 4 · 2013: 3 · 2012: 1
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion, public-domain)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- selective nerve stimulation, hybrid computational model, finite element analysis, peripheral nerve fibers, sciatic nerve, recruitment curves, selectivity index, rats
- MeSH terms
- Algorithms, Animals, Biophysics, Computer Simulation, Computers, Hybrid, Electric Stimulation, Electrodes, Implanted, Equipment Design, Models, Neurological, Neurons, Recruitment, Neurophysiological, Sciatic Nerve, Reproducibility of Results, Rats, Sprague-Dawley, Muscle, Skeletal, Finite Element Analysis, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review