Hand Pose Estimation by Fusion of Inertial and Magnetic Sensing Aided by a Permanent Magnet
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Tracking human body motions using inertial sensors has become a well-accepted method in ambulatory applications since the subject is not confined to a lab-bounded volume. However, a major drawback is the inability to estimate relative body positions over time because inertial sensor information only allows position tracking through strapdown integration, but does not provide any information about relative positions. In addition, strapdown integration inherently results in drift of the estimated position over time. We propose a novel method in which a permanent magnet combined with 3-D magnetometers and 3-D inertial sensors are used to estimate the global trunk orientation and relative pose of the hand with respect to the trunk. An Extended Kalman Filter is presented to fuse estimates obtained from inertial sensors with magnetic updates such that the position and orientation between the human hand and trunk as well as the global trunk orientation can be estimated robustly. This has been demonstrated in multiple experiments in which various hand tasks were performed. The most complex task in which simultaneous movements of both trunk and hand were performed resulted in an average rms position difference with an optical reference system of 19.7±2.2 mm whereas the relative trunk-hand and global trunk orientation error was 2.3±0.9 and 8.6±8.7 deg respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing
Sabatini, A. M. (2011) · Sensors · doi:10.3390/s110201489 · Cited by 349 · cited 1×
“magnetic information [5]–[7].”
Cited by
Qiu, S., Zhao, H., Jiang, N., Wang, Z., Liu, L., An, Y., Zhao, H., Miao, X., Liu, R., & Fortino, G. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.11.006 · Cited by 671
High-Fidelity Grasping in Virtual Reality using a Glove-based System
Liu, H., Zhang, Z., Xie, X., Zhu, Y., Liu, Y., Wang, Y., & Zhu, S.-C. (2019) · 2019 International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2019.8794230 · Cited by 73
“Efforts have also been made to improve pose sensing accuracy using filtering [18] and estimation algorithms ( e . g ., extended Kalman filter [19], [20]).”
MethodA glove-based system for studying hand-object manipulation via joint pose and force sensing
Liu, H., Xie, X., Millar, M., Edmonds, M., Gao, F., Zhu, Y., Santos, V. J., Rothrock, B., & Zhu, S.-C. (2017) · 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2017.8206575 · Cited by 60
“pose sensing accuracy using filtering [12] and estimation techniques like the extended Kalman filter [10], [11], [13].”
Method
Metadata
- Authors
- Kortier, H. G., Antonsson, J., Schepers, H. M., Gustafsson, F., & Veltink, P. H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2015-09
- Volume
- 23
- Issue
- 5
- Pages
- 796-806
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2126384236
- Cited by
- 52
- References
- 2
- FWCI
- 6.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hand Pose Estimation by Fusion of Inertial and Magnetic Sensing Aided by a Permanent Magnet. https://app.cochat.ai/papers/10.1109/tnsre.2014.2357579
- The paper
- Kortier, H. G., Antonsson, J., Schepers, H. M., Gustafsson, F., & Veltink, P. H. (2015). Hand Pose Estimation by Fusion of Inertial and Magnetic Sensing Aided by a Permanent Magnet. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2014.2357579
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.