A Computerized Method for Automatic Detection of Schizophrenia Using EEG Signals
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Diagnosis of schizophrenia (SZ) is traditionally performed through patient's interviews by a skilled psychiatrist. This process is time-consuming, burdensome, subject to error and bias. Hence the aim of this study is to develop an automatic SZ identification scheme using electroencephalogram (EEG) signals that can eradicate the aforementioned problems and support clinicians and researchers. This study introduces a methodology design involving empirical mode decomposition (EMD) technique for diagnosis of SZ from EEG signals to perfectly handle the behavior of non-stationary and nonlinear EEG signals. In this study, each EEG signal is decomposed into intrinsic mode functions (IMFs) by the EMD algorithm and then twenty-two statistical characteristics/features are calculated from these IMFs. Among them, five features are selected as significant feature applying Kruskal Wallis test. The performance of the obtained feature set is tested through several renowned classifierson a SZ EEG dataset. Among the considered classifiers, theensemble bagged tree performed as the best classifier producing 93.21% correct classification rate for SZ, with an overall accuracy of 89.59% for IMF 2. These results indicate that EEG signals discriminate SZ patients from healthy control (HC) subjects efficiently and have the potential to become a tool for the psychiatrist to support the positive diagnosis of SZ.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564 · cited 4×
“EMD describes the behavior of non-stationary and nonlinear signals (e.g. EEG signals) by decomposing them into intrinsic mode functions (IMFs) to obtain the instantaneous frequency (IF) of the intrinsic modes [21].”
BackgroundMethodInfluentialJames, S. L., Abate, D., Abate, K. H., Abay, S. M., Abbafati, C., Abbasi, N., Abbastabar, H., Abd-Allah, F., Abdela, J., Abdelalim, A., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)32279-7 · Cited by 13,867 · cited 1×
“ACCORDING to World Health Organization (WHO), schizophrenia (SZ) is a chronic and severe mental disorder affecting 20 million people worldwide [1], [2].”
BackgroundVos, T., Abajobir, A. A., Abate, K. H., Abbafati, C., Abbas, K. M., Abd-Allah, F., Abdulkader, R. S., Abdulle, A. M., Abebo, T. A., Abera, S. F., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32154-2 · Cited by 13,220
Excess early mortality in schizophrenia.
Laursen, T. M., Nordentoft, M., & Mortensen, P. B. (2014) · Annual Review of Clinical Psychology · doi:10.1146/annurev-clinpsy-032813-153657 · Cited by 913 · cited 1×
“The expected death of the SZ patients are 2-3 times higher than normal healthy people because of preventable physical diseases, such as cardiovascular disease, metabolic disease and infections [4].”
BackgroundSupport Vector Machines for Classification
Awad, M., & Khanna, R. (2015) · Efficient Learning Machines · doi:10.1007/978-1-4302-5990-9_3 · Cited by 543
Application of deep transfer learning for automated brain abnormality classification using MR images
Talo, M., Baloglu, U. B., Yıldırım, Ö., & Rajendra Acharya, U. (2019) · Cognitive Systems Research · doi:10.1016/j.cogsys.2018.12.007 · Cited by 507
Classification of Seizure and Nonseizure EEG Signals Using Empirical Mode Decomposition
Bajaj, V., & Pachori, R. B. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2181403 · Cited by 472 · cited 1×
“was employed in various abnormalities detection such as epileptic seizure [23]–[25], amyotrophic lateral sclerosis [26], [27], sleep apnea [28], alcoholism [29], stress [30] and mental”
MethodSelf-citationNonlinear feature based classification of speech under stress.
Zhou, G., Hansen, J. H. L., & Kaiser, J. F. (2001) · IEEE Transactions on Speech and Audio Processing · doi:10.1109/89.905995 · Cited by 409 · cited 2×
“This study considered first 10 channels called N100 [29], [30] as they are significant among all the channels.”
BackgroundMethodAdeniyi, D. A., Wei, Z., & Yongquan, Y. (2016) · Applied Computing and Informatics · doi:10.1016/j.aci.2014.10.001 · Cited by 406
Bagging, Boosting and Ensemble Methods
Bühlmann, P. (2012) · Handbook of Computational Statistics · doi:10.1007/978-3-642-21551-3_33 · Cited by 375
Cited by
Automatic Diagnosis of Schizophrenia in EEG Signals Using CNN-LSTM Models
Shoeibi, A., Sadeghi, D., Moridian, P., Ghassemi, N., Heras, J., Alizadehsani, R., Khadem, A., Kong, Y., Nahavandi, S., Zhang, Y.-D., et al. (2021) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2021.777977 · Cited by 197
“In recent years, various investigations have provided automated SZ diagnosis via EEG signals using artificial intelligence (AI) methods (Prasad et al., 2013; Shim et al., 2016; Chu et al., 2017; Alimardani et al., 2018; Devia et al., 2019; Jahmunah et al., 2019; Li et al., 2019; Naira and Alamo, 2019; Oh et al., 2019;…”
Self-citationSPWVD-CNN for Automated Detection of Schizophrenia Patients Using EEG Signals
Khare, S. K., Bajaj, V., & Acharya, U. R. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3070608 · Cited by 182
“Siuly et al. [34] used the EMD-based decomposition for feature extraction.”
MethodSelf-citationAutomatic Detection of Diabetic Eye Disease Through Deep Learning Using Fundus Images: A Survey
Sarki, R., Ahmed, K., Wang, H., & Zhang, Y. (2020) · IEEE Access · doi:10.1109/access.2020.3015258 · Cited by 176
Self-citationThe applied principles of EEG analysis methods in neuroscience and clinical neurology
Zhang, H., Zhou, Q.-Q., Chen, H., Hu, X.-Q., Li, W.-G., Bai, Y., Han, J.-X., Wang, Y., Liang, Z.-H., Chen, D., et al. (2023) · Military Medical Research · doi:10.1186/s40779-023-00502-7 · Cited by 160
Chen, Z., Liu, X., Yang, Q., Wang, Y.-J., Miao, K., Gong, Z., Yu, Y., Leonov, A., Liu, C., Feng, Z., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.1671 · Cited by 43
Chen, Z., Hu, B., Liu, X., Becker, B., Eickhoff, S. B., Miao, K., Gu, X., Tang, Y., Dai, X., Li, C., et al. (2023) · BMC Medicine · doi:10.1186/s12916-023-02941-4 · Cited by 35
Metadata
- Authors
- Siuly, S., Khare, S. K., Bajaj, V., Wang, H., & Zhang, Y.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2020-11
- Volume
- 28
- Issue
- 11
- Pages
- 2390-2400
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W3084085040
- Cited by
- 203
- References
- 48
- FWCI
- 14.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.