CoChat

Continuous Estimation of Human Knee Joint Angles by Fusing Kinematic and Myoelectric Signals

Open access
Sun, Ning, Cao, Menglin, Chen, Yuhao, Chen, Yanni, Wang, Jue, Wang, Qiong, Chen, Xiaocong, Liu, Tian · 2022 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 56

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Exoskeleton robot is an essential tool in active rehabilitation training for patients with lower limb motor dysfunctions. Accurate and real-time recognition in human motion intention is a great challenge in exoskeleton robot, which can be implemented by continues estimation of human joint angles. In this study, we innovatively proposed a novel feature-based convolutional neural network-bi-directional long-short term memory network (CNN-BiLSTM) model to predict the knee joint angles more accurately and in real time. We validated our method on a public dataset, including surface electromyography(sEMG) and inertial measurement unit (IMU) data of 10 healthy subjects during normal walking. Initially, features extraction from each modal data achieved feature-level fusion. Then the importance of each sEMG and IMU signal feature for knee joint angle prediction was quantified by ensemble feature scorer (EFS) and the number of features required for prediction while ensuring accuracy was simplified by profile likelihood maximization (PLM) algorithm. Finally, the CNN-BiLSTM model was created by using the determined simplest features to further fuse the spatio-temporal correlation of signals. The results indicated that the EFS and PLM algorithm could remove the feature redundancy perfectly and estimation performance would become better when bi-modal gait data were fused. For the estimation performance, the average root mean square error (RMSE), adjusted [Formula: see text] and pearson correlation coefficient (CC) of our algorithm were 4.07, 0.95, and 0.98, respectively, which was better than CNN, BiLSTM and other three traditional machine learning methods. In addition, the model test time was 62.47 ± 0.29 ms, which was less than the predicted horizon of 100 ms. The real-time performance and accuracy are satisfactory. Compared with previous works, our method has great advantages in feature selection and model design, which further improves the prediction accuracy. These promising results demonstrate that the proposed method has considerable potential to be applied to exoskeleton robot control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2022.3200485

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 56

Metadata

Authors
Sun, N., Cao, M., Chen, Y., Chen, Y., Wang, J., Wang, Q., Chen, X., & Liu, T.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2022
Volume
30
Pages
2446-2455
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W4292970538
Cited by
56
References
5
FWCI
2.97
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous Estimation of Human Knee Joint Angles by Fusing Kinematic and Myoelectric Signals. https://app.cochat.ai/papers/10.1109/tnsre.2022.3200485
The paper
Sun, N., Cao, M., Chen, Y., Chen, Y., Wang, J., Wang, Q., Chen, X., & Liu, T. (2022). Continuous Estimation of Human Knee Joint Angles by Fusing Kinematic and Myoelectric Signals. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2022.3200485

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.