CoChat

Rotational Skin Stretch Feedback: A Wearable Haptic Display for Motion

Bark, Karlin, Wheeler, Jason, Shull, Pete, Savall, Joan, Cutkosky, Mark · 2010 · IEEE Transactions on Haptics
Cited by 118

The DOI matches its Crossref record.

Abstract

We present a wearable haptic feedback device that imparts rotational skin stretch to the hairy skin, along with the results of psychophysical tests to determine its resolution and accuracy for motion display. Tracking experiments with visual markers reveal the pattern of skin motion and strain imparted by the device, confirming subjective impressions that the design represents a trade-off between perception at low stimulus levels and comfort at maximum stimulus levels. In an isolated environment, users were able to discriminate between different rotational displacements of stretch within two to five degrees, depending on the reference stimulus. In a more realistic setting, subjects were able to use feedback from the device to control the positioning of a virtual object within six degrees or ±6.5 degrees of the total range of motion. When subjects were passive and exposed to arbitrary rotations of the device, the accuracy was poorer, although it improved with training. The results suggest that wearable skin stretch devices can be an effective means of providing feedback about a user's controlled joint or limb motions for motion training and similar applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/toh.2010.21

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Bark, K., Wheeler, J., Shull, P., Savall, J., & Cutkosky, M.
Venue
IEEE Transactions on Haptics
Published
2010-07
Volume
3
Issue
3
Pages
166-176
ISSN
1939-1412 (ISSN-L)
OpenAlex
W2123676049
Cited by
118
References
0
FWCI
1.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.