The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Fast Decoupled Load Flow
Abstract
This paper describes a simple, very reliable and extremely fast load-flow solution method with a wide range of practical application. It is attractive for accurate or approximate off-and on-line routine and contingency calculations for networks of any size, and can be implemented efficiently on computers with restrictive core-store capacities. The method is a development on other recent work employing the MW-Θ/ MVAR-V decoupling principle, and its precise algorithmic form has been determined by extensive numerical studies. The paper gives details of the method's performance on a series of practical problems of up to 1080 buses. A solution to within 0.01 MW/MVAR maximum bus mismatches is normally obtained in 4 to 7 iterations, each iteration being equal in speed to 1½ Gauss-Seidel iterations or 1/5th of a Newton iteration. Correlations of general interest between the power-mismatch convergence criterion and actual solution accuracy are obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal Load Flow with Steady-State Security
Alsac, O., & Stott, B. (1974) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1974.293972 · Cited by 1,557
Self-citationPower Flow Solution by Newton's Method
Tinney, W., & Hart, C. (1967) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1967.291823 · Cited by 1,215
Direct solutions of sparse network equations by optimally ordered triangular factorization
Tinney, W. F., & Walker, J. (1967) · Proceedings of the IEEE · doi:10.1109/proc.1967.6011 · Cited by 811
Computer Methods in Power System Analysis
Dweck, E. E. (1969) · Electronics and Power · doi:10.1049/ep.1969.0079 · Cited by 590
Stott, B. (1972) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1972.293524 · Cited by 125
Self-citation
Cited by
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541
Security analysis and optimization
Stott, B., Alsac, O., & Monticelli, A. J. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13931 · Cited by 553
Self-citationThree-phase power flow calculations using the current injection method
Garcia, P. A. N., Pereira, J. L. R., Carneiro, S., da Costa, V. M., & Martins, N. (2000) · IEEE Transactions on Power Systems · doi:10.1109/59.867133 · Cited by 438
Usefulness of DC power flow for active power flow analysis
Purchala, K., Meeus, L., Van Dommelen, D., & Belmans, R. (2005) · IEEE Power Engineering Society General Meeting, 2005 · doi:10.1109/pes.2005.1489581 · Cited by 386
Optimal power dispatchߞA comprehensive survey
Happ, H. H. (1977) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/t-pas.1977.32397 · Cited by 310
Metadata
- Authors
- Stott, B., & Alsac, O.
- Venue
- IEEE Transactions on Power Apparatus and Systems
- Published
- 1974-05
- Volume
- PAS-93
- Issue
- 3
- Pages
- 859-869
- ISSN
- 0018-9510 (ISSN-L)
- OpenAlex
- W2105906451
- Cited by
- 1,522
- References
- 5
- FWCI
- 15.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast Decoupled Load Flow. https://app.cochat.ai/papers/10.1109/tpas.1974.293985
- The paper
- Stott, B., & Alsac, O. (1974). Fast Decoupled Load Flow. IEEE Transactions on Power Apparatus and Systems. https://doi.org/10.1109/tpas.1974.293985
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.