The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Harmonic Power Flow Studies Part I - Formulation and Solution
Abstract
The conventional Newton-Raphson power flow study has been reformulated to permit the inclusion of non-linear loads. These loads give rise to harmonic signals which propagate throughout the power system. The reformulation is based on the reduction-to zero of the mismatch active power and reactive voltamperes, the imbalahce current at harmonic frequencies, and the mismatch apparent voltamperbs. Conclusions on the existance of positive, negative, and zero sequence signals is made for harmonic frequencies. The harmonic power flow study formulation is illustrated for a three phase full wave bridge rectifier.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kimbark, E. W. (1971) · Medical Entomology and Zoology · Cited by 782
Energy Flow and Power Factor in Nonsinusoidal Circuits
Gibbon, M. A. (1980) · Electronics and Power · doi:10.1049/ep.1980.0145 · Cited by 144
Harmonic Power Flow Studies - Part II Implementation and Practical Application
Xia, D., & Heydt, G. T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317172 · Cited by 127
Self-citation
Cited by
Electrical power systems quality
(1996) · Choice Reviews Online · doi:10.5860/choice.34-0322 · Cited by 2,608
Passive Filters—Potentialities and Limitations
Das, J. C. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.821666 · Cited by 632
The Impact of Electric Vehicle Deployment on Load Management Straregies
Heydt, G. (1983) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1983.318071 · Cited by 147
Self-citation
Metadata
- Authors
- Xia, D., & Heydt, G.
- Venue
- IEEE Transactions on Power Apparatus and Systems
- Published
- 1982-06
- Volume
- PAS-101
- Issue
- 6
- Pages
- 1257-1265
- ISSN
- 0018-9510 (ISSN-L)
- OpenAlex
- W2155903355
- Cited by
- 278
- References
- 3
- FWCI
- 10.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.