Grid current regulation of a three-phase voltage source inverter with an LCL input filter
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Many grid connected power electronic systems, such as STATCOMs, UPFCs, and distributed generation system interfaces, use a voltage source inverter (VSI) connected to the supply network through a filter. This filter, typically a series inductance, acts to reduce the switching harmonics entering the distribution network. An alternative filter is a LCL network, which can achieve reduced levels of harmonic distortion at lower switching frequencies and with less inductance, and therefore has potential benefits for higher power applications. However, systems incorporating LCL filters require more complex control strategies and are not commonly presented in literature. This paper proposes a robust strategy for regulating the grid current entering a distribution network from a three-phase VSI system connected via a LCL filter. The strategy integrates an outer loop grid current regulator with inner capacitor current regulation to stabilize the system. A synchronous frame PI current regulation strategy is used for the outer grid current control loop. Linear analysis, simulation, and experimental results are used to verify the stability of the control algorithm across a range of operating conditions. Finally, expressions for ""harmonic impedance" of the system are derived to study the effects of supply voltage distortion on the harmonic performance of the system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,402
Blasko, V., & Kaura, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.568021 · Cited by 508
Cited by
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Evaluation of Current Controllers for Distributed Power Generation Systems
Timbus, A., Liserre, M., Teodorescu, R., Rodriguez, P., & Blaabjerg, F. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2012527 · Cited by 934
Dannehl, J., Wessels, C., & Fuchs, F. W. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2008774 · Cited by 747
Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter
Dannehl, J., Liserre, M., & Fuchs, F. W. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2081952 · Cited by 648
Metadata
- Authors
- Twining, E., & Holmes, D. G.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2003-05
- Volume
- 18
- Issue
- 3
- Pages
- 888-895
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2138198111
- Cited by
- 901
- References
- 2
- FWCI
- 13.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.