The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Stationary frame current regulation of PWM inverters with zero steady-state error
Abstract
Current regulators for AC inverters are commonly categorized as hysteresis, linear PI, or deadbeat predictive regulators, with a further sub-classification into stationary ABC frame and synchronous d-q frame implementations. Synchronous frame regulators are generally accepted to have a better performance than stationary frame regulators, as they operate on DC quantities and hence can eliminate steady-state errors. This paper establishes a theoretical connection between these two classes of regulators and proposes a new type of stationary frame regulator, the P+Resonant regulator, which achieves the same transient and steady-state performance as a synchronous frame PI regulator. The new regulator is applicable to both single-phase and three phase inverters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current control techniques for three-phase voltage-source PWM converters: a survey
Kazmierkowski, M. P., & Malesani, L. (1998) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.720325 · Cited by 2,125
Yuan, X., Allmeling, J., Merk, W., & Stemmler, H. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.883122 · Cited by 663
Sato, Y., Ishizuka, T., Nezu, K., & Kataoka, T. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.673717 · Cited by 265
Sato, Y., Ishizuka, T., Nezu, K., & Kataoka, T. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629051 · Cited by 208
Cited by
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Proportional-resonant controllers and filters for grid-connected voltage-source converters
Teodorescu, R., Blaabjerg, F., Liserre, M., & Loh, P. C. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20060008 · Cited by 1,646
A new single-phase PLL structure based on second order generalized integrator
Ciobotaru, M., Teodorescu, R., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1711988 · Cited by 1,189
Li, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.861185 · Cited by 1,101
Metadata
- Authors
- Zmood, D. N., & Holmes, D. G.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2003-05
- Volume
- 18
- Issue
- 3
- Pages
- 814-822
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2144081311
- Cited by
- 1,518
- References
- 4
- FWCI
- 19.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.