Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record.

Reduced Conductive EMI in Switched-Mode DC–DC Power Converters Without EMI Filters: PWM Versus Randomized PWM

Mihali, Franc, Kos, Dejan·2006·IEEE Transactions on Power Electronics

Abstract

This paper addresses improved electromagnetic compatibility (EMC) in switched-mode power converters (SMPCs), without using electromagnetic interference (EMI) filters. A practical solution is proposed for minimizing conductive EMI in a pulsewidth modulated (PWM), and random PWM dc-dc power converters. A comparative investigation is performed into the use of different random modulation schemes (driven by the DSP-2 board with the TMS320C32) as against the normal PWM. The effectiveness of randomization on spreading those dominating frequencies that normally exist in constant frequency PWM schemes is evaluated by power spectral density (PSD) estimations in the low-frequency range. Some parasitical- and topology-based EMI sources in devices are presented and frequency analysis is shown by using the discrete Fourier transform (DFT). SPICE simulations are also used to verify practical solutions for eliminating negative EMI sources and achieving EMC improvements. Finally, levels of conductive EMI are estimated with DFT, and experimentally verified to comply with the CISPR 25 (or EN 55025) regulations. Moreover, it is clearly shown, that limited speed PWM driving of the power switches with appropriate snubber circuits guarantees reduced conductive EMI. When considering the price and high EMC, in the final solution the power converter is driven by the mu-controller PIC16F876 with limited numerical and peripheral capabilities, where only normal PWM and randomized PWM can be implemented

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpel.2006.882910

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Mihali, F., & Kos, D.
Venue
IEEE Transactions on Power Electronics
Published
2006-11
Volume
21
Issue
6
Pages
1783-1794
ISSN
0885-8993 (ISSN-L)
OpenAlex
W2096238133
Cited by
161
References
0
FWCI
7.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduced Conductive EMI in Switched-Mode DC–DC Power Converters Without EMI Filters: PWM Versus Randomized PWM. https://app.cochat.ai/papers/10.1109/tpel.2006.882910
The paper
Mihali, F., & Kos, D. (2006). Reduced Conductive EMI in Switched-Mode DC–DC Power Converters Without EMI Filters: PWM Versus Randomized PWM. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2006.882910

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.