The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Systematic Topology Evaluation Methodology for High-Density Three-Phase PWM AC-AC Converters
Abstract
This paper presents a systematic evaluation approach of three-phase pulsewidth-modulated (PWM) ac–ac converter topologies for high-density applications. All major components and subsystems in a converter are considered and the interdependence of all the constraints and design parameters is systematically studied. The key design parameters, including switching frequency, modulation scheme, and passive values, are selected by considering their impacts on loss, harmonics, electromagnetic interference (EMI), control dynamics and stability, and protection. The component selection criteria as well as the physical design procedures are developed from the high-density standpoint. The concept of using the same inductor for harmonic suppression and EMI filtering is introduced in the design. With the proposed methodology, four converter topologies, a back-to-back voltage source converter (BTB-VSC), a nonregenerative three-level boost (Vienna-type) rectifier plus voltage source inverter (NTR-VSI), a back-to-back current source converter (BTB-CSC), and a 12-switch matrix converter, are analyzed and compared for high specific power using SiC devices. The evaluation results show that with the conditions specified in this paper, BTB-VSC and NTR-VSI have considerably lower loss, resulting in higher specific power than BTB-CSC and the matrix converter. The proposed methodology can be applied to other topologies with different comparison metrics and can be a useful tool for high-density topology selection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Venkatachalam, K., Sullivan, C. R., Abdallah, T., & Tacca, H. (2003) · 2002 IEEE Workshop on Computers in Power Electronics, 2002. Proceedings. · doi:10.1109/cipe.2002.1196712 · Cited by 1,145
Cited by
Friedli, T., Kolar, J. W., Rodriguez, J., & Wheeler, P. W. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2179278 · Cited by 402
Impact of Interleaving on AC Passive Components of Paralleled Three-Phase Voltage-Source Converters
Zhang, D., Wang, F., Burgos, R., Lai, R., & Boroyevich, D. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2045336 · Cited by 265
Self-citationZheng, L., Han, X., An, Z., Kandula, R. P., Kandasamy, K., Saeedifard, M., & Divan, D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3066908 · Cited by 84
Isolated ZVS High-Frequency-Link AC-AC Converter With a Reduced Switch Count
Keyhani, H., & Toliyat, H. A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2290544 · Cited by 30
Metadata
- Authors
- Lai, R., Wang, F., Burgos, R., Pei, Y., Boroyevich, D., Wang, B., Lipo, T. A., Immanuel, V. D., & Karimi, K. J.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2008-11
- Volume
- 23
- Issue
- 6
- Pages
- 2665-2680
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2167928781
- Cited by
- 210
- References
- 1
- FWCI
- 12.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Systematic Topology Evaluation Methodology for High-Density Three-Phase PWM AC-AC Converters. https://app.cochat.ai/papers/10.1109/tpel.2008.2005381
- The paper
- Lai, R., Wang, F., Burgos, R., Pei, Y., Boroyevich, D., Wang, B., Lipo, T. A., Immanuel, V. D., & Karimi, K. J. (2008). A Systematic Topology Evaluation Methodology for High-Density Three-Phase PWM AC-AC Converters. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2008.2005381
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.