Abstract
A sensorless three-level neutral-point-clamped inverter-fed induction motor drive is proposed in this paper. The conventional direct torque control (DTC) switching table fails to consider the circuit limitations, such as neutral-point-balance and smooth vector switching, caused by the topology of a three-level inverter. Two kinds of modified schemes for three-level DTC are proposed to solve these problems. They also provide performance enhancement while maintaining robustness and simplicity. Fuzzy logic control and the speed-adaptive flux observer (with novel gain and load toque observation) are introduced to enhance the performance of the system. The issue of large starting current is investigated and solved by introducing the technique of preexcitation. A 32-bit fixed-point DSP-based motor drive is developed to achieve high-performance sensorless control over a wide speed range. The effectiveness of the proposed schemes is confirmed by simulation implementation and experimental validation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Quick-Response and High-Efficiency Control Strategy of an Induction Motor
Takahashi, I., & Noguchi, T. (1986) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1986.4504799 · Cited by 3,407
Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385
Direct self-control (DSC) of inverter-fed induction machine
Depenbrock, M. (1988) · IEEE Transactions on Power Electronics · doi:10.1109/63.17963 · Cited by 1,705
Direct Torque Control of PWM Inverter-Fed AC Motors—A Survey
Buja, G. S., & Kazmierkowski, M. P. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.831717 · Cited by 1,267
Zhang, Y., & Zhu, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2059047 · Cited by 389
Self-citationComparisons of Space-Vector Modulation and Carrier-Based Modulation of Multilevel Inverter
Yao, W., Hu, H., & Lu, Z. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.911865 · Cited by 347
Speed-sensorless direct torque control of induction motors using an adaptive flux observer
Maes, J., & Melkebeek, J. A. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.845053 · Cited by 305
Speed sensorless direct torque control of induction motors using an adaptive flux observer
Maes, J., & Melkebeek, J. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.799165 · Cited by 267
Cited by
Zhao, Y., Wei, C., Zhang, Z., & Qiao, W. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2280572 · Cited by 274
A Review of Modulation and Control Techniques for Multilevel Inverters in Traction Applications
Poorfakhraei, A., Narimani, M., & Emadi, A. (2021) · IEEE Access · doi:10.1109/access.2021.3056612 · Cited by 179
“Although the DTC method has a faster dynamic response compared to FOC, the torque ripple is shown to be higher with the DTC scheme.”
InfluentialGuazzelli, P. R. U., de Andrade Pereira, W. C., de Oliveira, C. M. R., de Castro, A. G., & de Aguiar, M. L. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2834304 · Cited by 178
“The analysis of the observer stability and robustness can be found in [35]”
Background
Metadata
- Authors
- Zhang, Y., Zhu, J., Zhao, Z., Xu, W., & Dorrell, D. G.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-03
- Volume
- 27
- Issue
- 3
- Pages
- 1502-1513
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2071164188
- Cited by
- 279
- References
- 8
- FWCI
- 11.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.