A Soft Switching Three-phase Current-fed Bidirectional DC-DC Converter With High Efficiency Over a Wide Input Voltage Range
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this paper, a three-phase current-fed dual-active-bridge (DAB) bidirectional DC-DC converter is presented. Compared to the voltage source DAB converter, the proposed converter allows low RMS current and maintains zero voltage switching (ZVS) in the whole operating range by keeping the ratio between primary side and secondary side DC-link voltage constant, leading to high efficient energy conversion over a wide input voltage range. In addition, the ZVS conditions can be maintained using small DC inductors and the input current ripple still remains small because of high DC inductor current ripples being alleviated by three-phase interleaving structure. Furthermore, the proposed topology with Y-Y connected transformers is proven to have better current sharing capability compared with other three-phase topologies with different transformer connections. The operation mode analysis, soft switching conditions, and hardware design guidelines are derived in this paper. A 6-kW hardware prototype with input voltage range of 24~48 V and rated 288 V output voltage is developed and tested in the laboratory. The experimental results verified that the proposed converter could maintain high efficiency over a wide input voltage and power range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new ZVS bidirectional DC-DC converter for fuel cell and battery application
Peng, F. Z., Li, H., Su, G.-J., & Lawler, J. S. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820550 · Cited by 782 · cited 3×
“Another current-fed dual-half-bridge (DHB) converter is proposed for fuel cell application [16], in which the DC-link voltage of low voltage side can be controlled by adjusting the duty cycle.”
BackgroundMethodInfluentialSelf-citationKrismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 1×
“For example, it has been used in hybrid electric vehicles (HEVs) as auxiliary an power supply to replace the starter/alternator and to provide galvanic isolation between the low voltage battery and high voltage bus [2], [3].”
Method
Cited by
Gowaid, I. A., Adam, G. P., Massoud, A. M., Ahmed, S., Holliday, D., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2306453 · Cited by 356
Xu, L., Guerrero, J., Lashab, A., Wei, B., Bazmohammadi, N., Vasquez, J., & Abusorrah, A. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3128417 · Cited by 262
“Voltage stress vdc /N and vdc vdc /N vdc /2 and vdc Inductor and transformer number N transformers 12 inductors and one transformer One transformer Capacitor number 2N 12N 3 Switching frequency Hundreds Hz to kHz [133] Hundreds Hz to kHz [134] Hundreds Hz [112] Number of switches 8N 16N 32N 10 Control complexity High…”
BackgroundCirculating Current and ZVS-on of a Dual Active Bridge DC-DC Converter: A Review
Shao, S., Chen, H., Wu, X., Zhang, J., & Sheng, K. (2019) · IEEE Access · doi:10.1109/access.2019.2911009 · Cited by 200
“A CF-DAB is easy to interleave more phases to reduce size of input dc inductors and dc link capacitors [74].”
MethodA bidirectional three-phase push–pull converter with dual asymmetrical PWM method
Kwon, M., Park, J., & Choi, S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2431273 · Cited by 47
“The PWM plus phase shift (PPS) method [6] has been applied to the three-phase BDC based on the current-fed converter on the LVS and the voltage-fed converter on the HVS [34], [35].”
Method
Metadata
- Authors
- Wang, Z., & Li, H.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-02
- Volume
- 27
- Issue
- 2
- Pages
- 669-684
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2079347530
- Cited by
- 200
- References
- 2
- FWCI
- 8.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.