The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Safety Enhanced, High Step-Up DC–DC Converter for AC Photovoltaic Module Application
Abstract
Within the photovoltaic (PV) power-generation market, the ac PV module has shown obvious growth. However, a high voltage gain converter is essential for the module's grid connection through a dc-ac inverter. This paper proposes a converter that employs a floating active switch to isolate energy from the PV panel when the ac module is off; this particular design protects installers and users from electrical hazards. Without extreme duty ratios and the numerous turns-ratios of a coupled inductor, this converter achieves a high step-up voltage-conversion ratio; the leakage inductor energy of the coupled inductor is efficiently recycled to the load. These features explain the module's high-efficiency performance. The detailed operating principles and steady-state analyses of continuous, discontinuous, and boundary conduction modes are described. A 15 V input voltage, 200 V output voltage, and 100 W output power prototype circuit of the proposed converter has been implemented; its maximum efficiency is up to 95.3% and full-load efficiency is 92.3%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of Nonisolated High-Step-Up DC/DC Converters in Photovoltaic Grid-Connected Applications
Li, W., & He, X. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049715 · Cited by 1,423
Cited by
High Step-Up DC–DC Converter With Active Switched-Inductor and Passive Switched-Capacitor Networks
Salvador, M. A., Lazzarin, T. B., & Coelho, R. F. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2782239 · Cited by 438
Forouzesh, M., Shen, Y., Yari, K., Siwakoti, Y. P., & Blaabjerg, F. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2746750 · Cited by 431
Zhao, Y., Ball, R., Mosesian, J., de Palma, J.-F., & Lehman, B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2364203 · Cited by 331
Novel High Step-Up DC–DC Converter With Coupled-Inductor and Switched-Capacitor Techniques
Hsieh, Y.-P., Chen, J.-F., Liang, T.-J., & Yang, L.-S. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2151828 · Cited by 326
Self-citationA High Step-Up Converter With a Voltage Multiplier Module for a Photovoltaic System
Tseng, K.-C., Huang, C.-C., & Shih, W.-Y. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2217157 · Cited by 272
Metadata
- Authors
- Chen, S.-M., Liang, T.-J., Yang, L.-S., & Chen, J.-F.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-04
- Volume
- 27
- Issue
- 4
- Pages
- 1809-1817
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2131453455
- Cited by
- 162
- References
- 1
- FWCI
- 11.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.