The DOI matches its Crossref record.
Improved Active Frequency Drift Anti-islanding Detection Method for Grid Connected Photovoltaic Systems
Open accessAbstract
As more distributed generators join the utility grid, the concern of possible undetected islanding operation increases. This concern is due to the safety hazards this phenomenon imposes on the personnel and equipment. Passive anti-islanding detection methods monitor grid parameters to detect islanding, whereas active methods inject a perturbation into the current waveform to drive these parameters out of limit when islanding occurs. The performance of active methods, such as conventional active frequency drift (AFD), is limited by the amount of total harmonic distortion (THD) they inject into the grid, which defines its nondetection zone. In this paper, an improved AFD anti-islanding method is presented based on a different current distortion injection waveform. The proposed method generates 30% less THD compared to classic AFD, resulting in faster island detection and improved nondetection zone. The performance of the proposed method is derived analytically, simulated using Matlab and verified experimentally using a prototype setup. A single-phase grid-tied photovoltaic distributed generation system is used for the simulation and experimental setup, and considered as potential application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kouro, S., Leon, J. I., Vinnikov, D., & Franquelo, L. G. (2015) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2014.2376976 · Cited by 1,197
Self-citationSupport Vector Machine-Based Islanding and Grid Fault Detection in Active Distribution Networks
Baghaee, H. R., Mlakic, D., Nikolovski, S., & Dragicevic, T. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2916621 · Cited by 235
Metadata
- Authors
- Yafaoui, A., Wu, B., & Kouro, S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-05
- Volume
- 27
- Issue
- 5
- Pages
- 2367-2375
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2054698458
- Cited by
- 214
- References
- 0
- FWCI
- 10.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.