The DOI matches its Crossref record.
Improved Voltage-Vector Sequences on Dead-Beat Predictive Direct Power Control of Reversible Three-Phase Grid-Connected Voltage-Source Converters
Abstract
This paper presents a dead-beat predictive direct power control (DPC) strategy and its improved voltage-vector sequences for reversible three-phase grid-connected voltage-source converters (VSCs). The instantaneous variation rates of active and reactive powers, by applying each converter voltage vector in 12 different sectors, are deduced and analyzed. Based on the power variation rates, it is found that the values of the predicted duration times for the two conventional active converter voltage vectors are less than zero when the grid-connected VSC operates as either a rectifier or an inverter. In order to solve this issue, two new alternative vector sequences are proposed and compared. Experimental results on a 1.5 kW reversible grid-connected VSC system are presented to validate the feasibility of the proposed voltage-vector sequences on the dead-beat predictive DPC strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Essence of Three-Phase PFC Rectifier Systems—Part I
Kolar, J. W., & Friedli, T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2197867 · Cited by 788
Hou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
A survey on control of electric power distributed generation systems for microgrid applications
Bouzid, A. M., Guerrero, J. M., Cheriti, A., Bouhamida, M., Sicard, P., & Benghanem, M. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.01.016 · Cited by 401
Virtual Direct Power Control Scheme of Dual Active Bridge DC–DC Converters for Fast Dynamic Response
Song, W., Hou, N., & Wu, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2682982 · Cited by 256
Gong, Z., Wu, X., Dai, P., & Zhu, R. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2844836 · Cited by 106
Metadata
- Authors
- Hu, J., & Zhu, Z. Q.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-01
- Volume
- 28
- Issue
- 1
- Pages
- 254-267
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1982857763
- Cited by
- 170
- References
- 0
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved Voltage-Vector Sequences on Dead-Beat Predictive Direct Power Control of Reversible Three-Phase Grid-Connected Voltage-Source Converters. https://app.cochat.ai/papers/10.1109/tpel.2012.2194512
- The paper
- Hu, J., & Zhu, Z. Q. (2013). Improved Voltage-Vector Sequences on Dead-Beat Predictive Direct Power Control of Reversible Three-Phase Grid-Connected Voltage-Source Converters. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2012.2194512
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.