The DOI matches its Crossref record.
A Family of Neutral Point Clamped Full-Bridge Topologies for Transformerless Photovoltaic Grid-Tied Inverters
Abstract
Transformerless inverter topologies have attracted more attentions in photovoltaic (PV) generation system since they feature high efficiency and low cost. In order to meet the safety requirement for transformerless grid-tied PV inverters, the leakage current has to be tackled carefully. Neutral point clamped (NPC) topology is an effective way to eliminate the leakage current. In this paper, two types of basic switching cells, the positive neutral point clamped cell and the negative neutral point clamped cell, are proposed to build NPC topologies, with a systematic method of topology generation given. A family of single-phase transformerless full-bridge topologies with low-leakage current for PV grid-tied NPC inverters is derived including the existing oH5 and some new topologies. A novel positive–negative NPC (PN-NPC) topology is analyzed in detail with operational modes and modulation strategy given. The power losses are compared among the oH5, the full-bridge inverter with dc bypass (FB-DCBP) topology, and the proposed PN-NPC topologies. A universal prototype for these three NPC-type topologies mentioned is built to evaluate the topologies at conversion efficiency and the leakage current characteristic. The PN-NPC topology proposed exhibits similar leakage current with the FB-DCBP, which is lower than that of the oH5 topology, and features higher efficiency than both the oH5 and the FB-DCBP topologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Comparison and Analysis of Single-Phase Transformerless Grid-Connected PV Inverters
Freddy, T. K. S., Rahim, N. A., Hew, W.-P., & Che, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2294953 · Cited by 332
Reviews on multilevel converter and modulation techniques
Hasan, N. S., Rosmin, N., Osman, D. A. A., & Musta’amal@Jamal, A. H. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.163 · Cited by 178
Power electronics - the key technology for renewable energy system integration
Blaabjerg, F., Yang, Y., Ma, K., & Wang, X. (2015) · 2015 International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2015.7418680 · Cited by 148
Metadata
- Authors
- Zhang, L., Sun, K., Feng, L., Wu, H., & Xing, Y.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-02
- Volume
- 28
- Issue
- 2
- Pages
- 730-739
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2089158133
- Cited by
- 360
- References
- 0
- FWCI
- 18.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Family of Neutral Point Clamped Full-Bridge Topologies for Transformerless Photovoltaic Grid-Tied Inverters. https://app.cochat.ai/papers/10.1109/tpel.2012.2205406
- The paper
- Zhang, L., Sun, K., Feng, L., Wu, H., & Xing, Y. (2013). A Family of Neutral Point Clamped Full-Bridge Topologies for Transformerless Photovoltaic Grid-Tied Inverters. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2012.2205406
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.