The DOI matches its Crossref record.
Dynamic and Balanced Control of Three-Phase High-Power Dual-Active Bridge DC–DC Converters in DC-Grid Applications
Abstract
The three-phase dual-active bridge (DAB) is a dc–dc converter, which provides galvanic isolation, inherent soft-switching capability, and small filter size. In this study, the dynamic behavior of three-phase DAB is analyzed and a dynamic control strategy is developed. Furthermore, a compensation technique is implemented to compensate unbalanced transformer phase currents. The latter is often caused by asymmetric leakage inductances. State space averaging and first harmonic approximation models, both for the steady state and transient analysis, are developed to describe the dynamic behavior of the three-phase DAB. The accuracy of the models is compared with a detailed circuit simulation and the benefits of each model are identified. When the transferred power of the DAB changes fast, the transformer currents can become unbalanced, leading to oscillations in the output current. A unique control method is presented, which allows settling of the transformer currents within one-third of the switching period. Additionally, the transformer currents stay symmetrical and oscillations are avoided. Based on this fast current control, an outer voltage controller is designed. The comparison of the control system using the fast current control and the conventional quasi-steady-state control demonstrates the potential advantages of the new approach under dynamic conditions. In practice, it is difficult to achieve completely symmetrical short-circuit impedances in a high-power medium-voltage transformer. Asymmetric leakage inductances, however, result in unbalanced phase currents and higher dc current ripple in a three-phase DAB. The new control scheme that is developed here can be extended to compensate any unbalances in the transformer. This approach enables effectively the balancing of the three-phase currents. The new control schemes are experimentally verified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Future on Power Electronics for Wind Turbine Systems
Blaabjerg, F., & Ma, K. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2275978 · Cited by 860
Modeling and Advanced Control of Dual-Active-Bridge DC–DC Converters: A Review
Shao, S., Chen, L., Shan, Z., Gao, F., Chen, H., Sha, D., & Dragičević, T. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3108157 · Cited by 488
Engel, S. P., Stieneker, M., Soltau, N., Rabiee, S., Stagge, H., & De Doncker, R. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310656 · Cited by 443
Self-citation
Metadata
- Authors
- Engel, S. P., Soltau, N., Stagge, H., & De Doncker, R. W.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-04
- Volume
- 28
- Issue
- 4
- Pages
- 1880-1889
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2080838776
- Cited by
- 232
- References
- 0
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic and Balanced Control of Three-Phase High-Power Dual-Active Bridge DC–DC Converters in DC-Grid Applications. https://app.cochat.ai/papers/10.1109/tpel.2012.2209461
- The paper
- Engel, S. P., Soltau, N., Stagge, H., & De Doncker, R. W. (2013). Dynamic and Balanced Control of Three-Phase High-Power Dual-Active Bridge DC–DC Converters in DC-Grid Applications. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2012.2209461
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.