Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 363

The DOI matches its Crossref record.

High Reliability and Efficiency Single-Phase Transformerless Inverter for Grid-Connected Photovoltaic Systems

Gu, Bin, Dominic, Jason, Lai, Jih-Sheng, Chen, Chien-Liang, LaBella, Thomas, Chen, Baifeng·2013·IEEE Transactions on Power Electronics

Abstract

This paper presents a high-reliability single-phase transformerless grid-connected inverter that utilizes superjunction MOSFETs to achieve high efficiency for photovoltaic applications. The proposed converter utilizes two split ac-coupled inductors that operate separately for positive and negative half grid cycles. This eliminates the shoot-through issue that is encountered by traditional voltage source inverters, leading to enhanced system reliability. Dead time is not required at both the high-frequency pulsewidth modulation switching commutation and the grid zero-crossing instants, improving the quality of the output ac-current and increasing the converter efficiency. The split structure of the proposed inverter does not lead itself to the reverse-recovery issues for the main power switches and as such superjunction MOSFETs can be utilized without any reliability or efficiency penalties. Since MOSFETs are utilized in the proposed converter high efficiency can be achieved even at light load operations achieving a high California energy commission (CEC) or European union efficiency of the converter system. It also has the ability to operate at higher switching frequencies while maintaining high efficiency. The higher operating frequencies with high efficiency enables reduced cooling requirements and results in system cost savings by shrinking passive components. With two additional ac-side switches conducting the currents during the freewheeling phases, the photovoltaic array is decoupled from the grid. This reduces the high-frequency common-mode voltage leading to minimized ground loop leakage current. The operation principle, common-mode characteristic and design considerations of the proposed transformerless inverter are illustrated. The total losses of the power semiconductor devices of several existing transformerless inverters which utilize MOSFETs as main switches are evaluated and compared. The experimental results with a 5 kW prototype circuit show 99.0% CEC efficiency and 99.3% peak efficiency with a 20 kHz switching frequency. The high reliability and efficiency of the proposed converter makes it very attractive for single-phase transformerless photovoltaic inverter applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpel.2012.2214237

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 363

Metadata

Authors
Gu, B., Dominic, J., Lai, J.-S., Chen, C.-L., LaBella, T., & Chen, B.
Venue
IEEE Transactions on Power Electronics
Published
2013-05
Volume
28
Issue
5
Pages
2235-2245
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W1974550938
Cited by
363
References
0
FWCI
22.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Reliability and Efficiency Single-Phase Transformerless Inverter for Grid-Connected Photovoltaic Systems. https://app.cochat.ai/papers/10.1109/tpel.2012.2214237
The paper
Gu, B., Dominic, J., Lai, J.-S., Chen, C.-L., LaBella, T., & Chen, B. (2013). High Reliability and Efficiency Single-Phase Transformerless Inverter for Grid-Connected Photovoltaic Systems. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2012.2214237

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.