The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
A DC–DC Multiport-Converter-Based Solid-State Transformer Integrating Distributed Generation and Storage
Abstract
The Solid-state transformer (SST) has been proposed by researchers to replace the regular distribution transformer in the future smart grid. The SST provides ports for the integration of storage and distributed generation (DG), e.g., photovoltaic (PV), and enables the implementation of power quality features. This paper proposes a SST topology based on a quad-active-bridge (QAB) converter which not only provides isolation for the load, but also for DG and storage. A gyrator-based average model is developed for a general multiactive-bridge (MAB) converter, and expressions to determine the power rating of the MAB ports are derived. These results are then applied to analyze the QAB converter. For the control of the dc-dc stage of the proposed QAB-based SST integrating PV and battery, a technique that accounts for the cross-coupling characteristics of the QAB converter in order to improve the regulation of the high-voltage-dc link is introduced. This is done by transferring the disturbances onto the battery. The control loops are designed using single-input single-output techniques with different bandwidths. The dynamic performance of the control strategy is verified through extensive simulation and experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multivariable Feedback Control: Analysis and Design
Skogestad, S., & Postlethwaite, I. (1996) · Cited by 6,312
Power electronics converters, applications and design
Robinson, F. V. P. (1997) · Microelectronics Journal · doi:10.1016/s0026-2692(97)87859-7 · Cited by 5,075
A three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535
Naidu, & Kolmanovsky (2004) · Applied Mechanics Reviews · doi:10.1115/1.1641776 · Cited by 879
Family of multiport bidirectional DC–DC converters
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20050362 · Cited by 488
Coleman, M., Lee, C. K., Zhu, C., & Hurley, W. G. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899926 · Cited by 473
Three-Port Triple-Half-Bridge Bidirectional Converter With Zero-Voltage Switching
Tao, H., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915023 · Cited by 404
Topology comparison for Solid State Transformer implementation
Falcones, S., Mao, X., & Ayyanar, R. (2010) · IEEE PES General Meeting · doi:10.1109/pes.2010.5590086 · Cited by 283
Self-citationDesign and development of Generation-I silicon based Solid State Transformer
Bhattacharya, S., Zhao, T., Wang, G., Dutta, S., Baek, S., Du, Y., Parkhideh, B., Zhou, X., & Huang, A. Q. (2010) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2010.5433455 · Cited by 156
270 kVA Solid State Transformer Based on 10 kV SiC Power Devices
Zhao, T., Yang, L., Wang, J., & Huang, A. Q. (2007) · IEEE Electric Ship Technologies Symposium (ESTS) · doi:10.1109/ests.2007.372077 · Cited by 133
Cited by
Applicability of solid-state transformers in today's and future distribution grids
Huber, J. E., & Kolar, J. W. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2738610 · Cited by 506
Review of Multiport Converters for Solar and Energy Storage Integration
Bhattacharjee, A. K., Kutkut, N., & Batarseh, I. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2830788 · Cited by 423
Gu, C., Zheng, Z., Xu, L., Wang, K., & Li, Y. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2416212 · Cited by 221
Circulating Current and ZVS-on of a Dual Active Bridge DC-DC Converter: A Review
Shao, S., Chen, H., Wu, X., Zhang, J., & Sheng, K. (2019) · IEEE Access · doi:10.1109/access.2019.2911009 · Cited by 200
Zhao, B., Song, Q., & Liu, W. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2350459 · Cited by 143
Metadata
- Authors
- Falcones, S., Ayyanar, R., & Mao, X.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-05
- Volume
- 28
- Issue
- 5
- Pages
- 2192-2203
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2057175642
- Cited by
- 501
- References
- 21
- FWCI
- 14.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A DC–DC Multiport-Converter-Based Solid-State Transformer Integrating Distributed Generation and Storage. https://app.cochat.ai/papers/10.1109/tpel.2012.2215965
- The paper
- Falcones, S., Ayyanar, R., & Mao, X. (2013). A DC–DC Multiport-Converter-Based Solid-State Transformer Integrating Distributed Generation and Storage. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2012.2215965
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.