Characteristic Investigation and Control of a Modular Multilevel Converter-Based HVDC System Under Single-Line-to-Ground Fault Conditions
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents the analysis and control of a multilevel modular converter (MMC)-based HVDC transmission system under three possible single-line-to-ground fault conditions, with special focus on the investigation of their different fault characteristics. Considering positive-, negative-, and zero-sequence components in both arm voltages and currents, the generalized instantaneous power of a phase unit is derived theoretically according to the equivalent circuit model of the MMC under unbalanced conditions. Based on this model, a novel double-line frequency dc-voltage ripple suppression control is proposed. This controller, together with the negative- and zero-sequence current control, could enhance the overall fault-tolerant capability of the HVDC system without additional cost. To further improve the fault-tolerant capability, the operation performance of the HVDC system with and without single-phase switching is discussed and compared in detail. Simulation results from a three-phase MMC-HVDC system generated with MATLAB/Simulink are provided to support the theoretical analysis and proposed control schemes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Guan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549
Cited by
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
Gong, Z., Wu, X., Dai, P., & Zhu, R. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2844836 · Cited by 106
Sliding Mode Control of the Modular Multilevel Converter
Yang, Q., Saeedifard, M., & Perez, M. A. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2818657 · Cited by 89
Steady-State Modeling of Modular Multilevel Converter Under Unbalanced Grid Conditions
Shi, X., Wang, Z., Liu, B., Li, Y., Tolbert, L. M., & Wang, F. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2629472 · Cited by 73
“1, zero-sequence current will be blocked under unbalanced grid conditions, and no corresponding current control is required [25].”
BackgroundSelf-citationA Postfault Strategy to Control the Modular Multilevel Converter Under Submodule Failure
Yang, Q., Qin, J., & Saeedifard, M. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2449875 · Cited by 69
“Operation and control of the MMC under unbalanced grid conditions have been studied and investigated in [19]–[24].”
Background
Metadata
- Authors
- Shi, X., Wang, Z., Liu, B., Liu, Y., Tolbert, L. M., & Wang, F.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-01
- Volume
- 30
- Issue
- 1
- Pages
- 408-421
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2071333862
- Cited by
- 173
- References
- 2
- FWCI
- 11.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characteristic Investigation and Control of a Modular Multilevel Converter-Based HVDC System Under Single-Line-to-Ground Fault Conditions. https://app.cochat.ai/papers/10.1109/tpel.2014.2323360
- The paper
- Shi, X., Wang, Z., Liu, B., Liu, Y., Tolbert, L. M., & Wang, F. (2015). Characteristic Investigation and Control of a Modular Multilevel Converter-Based HVDC System Under Single-Line-to-Ground Fault Conditions. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2014.2323360
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.