Multilevel Medium-Frequency Link Inverter for Utility Scale Photovoltaic Integration
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
A multilevel topology with medium-frequency ac link for medium-voltage grid integration of utility photovoltaic (PV) plants is discussed in this paper. A megawatt-scale PV plant is divided into many zones, each comprising of two series-connected arrays. Each zone employs a medium-frequency transformer with three secondaries, which interface with the three phases of the medium voltage grid. An insulated-gate bipolar transistor full-bridge inverter feeds the MF transformer. The voltages at the transformer secondaries are then converted to three-phase line frequency ac by three full-bridge ac-ac converters. Second line frequency harmonic power does not appear in the dc bus, thereby reducing the dc capacitor size. Cascading several such cells, a high-quality multilevel medium-voltage output is generated. A new control method is proposed for the cascaded multilevel converter during partial shading while minimizing the switch ratings. The proposed topology eliminates the need for line frequency transformer isolation and reduces the dc bus capacitor size, while improving the power factor and energy yield. This paper presents the analysis, design example, and operation of a 10-MW utility PV system with experimental results on a scaled-down laboratory prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344 · cited 1×
“This system suffers from some disadvantages such as the dc bus voltage being limited due to safety regulations (1000 V in EU and 600 V in the USA) [7], [8].”
BackgroundVillanueva, E., Correa, P., Rodriguez, J., & Pacas, M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029579 · Cited by 795
Chavarria, J., Biel, D., Guinjoan, F., Meza, C., & Negroni, J. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2186108 · Cited by 391 · cited 1×
“eliminate these imbalances and process different powers [16], [18], [20], [31]–[36].”
BackgroundMultilevel converters for single-phase grid connected photovoltaic systems-an overview
Calais, M., & Agelidis, V. G. (2002) · IEEE International Symposium on Industrial Electronics. Proceedings. ISIE'98 (Cat. No.98TH8357) · doi:10.1109/isie.1998.707781 · Cited by 380 · cited 2×
“These topologies can also process unbalanced power among phases or the cascaded cells [16], [18], [20].”
BackgroundResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362
A New Simplified Multilevel Inverter Topology for DC–AC Conversion
Ceglia, G., Guzman, V., Sanchez, C., Ibanez, F., Walter, J., & Gimenez, M. I. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.880303 · Cited by 327
Mei, J., Xiao, B., Shen, K., Tolbert, L. M., & Zheng, J. Y. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2243758 · Cited by 319 · cited 1×
“Multilevel NPC topologies [11]–[14] and cascaded multilevel topologies [15]–[21] have also been proposed which process power from individual arrays rather than a large field.”
BackgroundBusquets‐Monge, S., Rocabert, J., Rodríguez, P., Alepuz, S., & Bordonau, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924011 · Cited by 316 · cited 1×
“Diode clamped topologies were proposed in [9] and [10] which enable individual array MPPT control and provide a better quality output voltage waveform than a full-bridge inverter.”
BackgroundMulticarrier PWM With DC-Link Ripple Feedforward Compensation for Multilevel Inverters
Kouro, S., Lezana, P., Angulo, M., & Rodriguez, J. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.911834 · Cited by 185
Control of a cascaded H-bridge multilevel converter for grid connection of photovoltaic systems
Kouro, S., Wu, B., Moya, A., Villanueva, E., Correa, P., & Rodríguez, J. (2009) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2009.5415332 · Cited by 159 · cited 2×
“These topologies can also process unbalanced power among phases or the cascaded cells [16], [18], [20].”
BackgroundA Solar Power Generation System With a Seven-Level Inverter
Wu, J., & Chou, C.-W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2279880 · Cited by 148
Inoue, S., & Akagi, H. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1711782 · Cited by 137
Classification, terminology, and application of the modular multilevel cascade converter (MMCC)
Akagi, H. (2010) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2010.5543243 · Cited by 128
Liu, L., Li, H., Wu, Z., & Zhou, Y. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2168544 · Cited by 109
Harada, K., Anan, F., Yamasaki, K., Jinno, M., Kawata, Y., & Nakashima, T. (2002) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1996.548755 · Cited by 99 · cited 3×
“In an n inverter system, the real power available to each inverter is represented as Pi , and the sum of all powers gives the total system real power Ptotal = n∑ i=1 Pi.”
MethodInfluentialElasser, A., Agamy, M. S., Sabate, J. A., Steigerwald, R. L., Fisher, R., & Todorovic, M. H. (2010) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2010.5675108 · Cited by 87 · cited 2×
“The power conversion and grid integration for MW scale PV power plants become more complex as size of the installation increases [4],”
BackgroundNPC multilevel multistring topology for large scale grid connected photovoltaic systems
Kouro, S., Asfaw, K. M., Goldman, R., Snow, R., Wu, B., & Rodríguez, J. (2010) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2010.5545744 · Cited by 84 · cited 1×
“Multilevel NPC topologies [11]–[14] and cascaded multilevel topologies [15]–[21] have also been proposed which process power from individual arrays rather than a large field.”
BackgroundAggeler, D., Biela, J., Inoue, S., Akagi, H., & Kolar, J. W. (2007) · Power Conversion Conference · doi:10.1109/pccon.2007.373015 · Cited by 82
Multilevel-Clamped Multilevel Converters (MLC $^2$ )
Rodríguez, P., Bellar, M. D., Aguilar, R. S. M., Busquets‐Monge, S., & Blaabjerg, F. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2172224 · Cited by 54
A new multilevel converter for Megawatt scale solar photovoltaic utility integration
Krishnamoorthy, H. S., Essakiappan, S., Enjeti, P. N., Balog, R. S., & Ahmed, S. (2012) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2012.6166008 · Cited by 49
Self-citationXiao, B., Hang, L., Riley, C., Tolbert, L. M., & Ozpineci, B. (2013) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2013.6520251 · Cited by 42 · cited 2×
“These topologies can also process unbalanced power among phases or the cascaded cells [16], [18], [20].”
BackgroundA bipolar two-stage photovoltaic system based on three-level neutral-point clamped converter
Ghoddami, H., & Yazdani, A. (2012) · IEEE Power and Energy Society General Meeting (PESGM) · doi:10.1109/pesgm.2012.6344886 · Cited by 21
Cited by
A review of photovoltaic systems: Design, operation and maintenance
Hernández-Callejo, L., Gallardo-Saavedra, S., & Alonso-Gómez, V. (2019) · Solar Energy · doi:10.1016/j.solener.2019.06.017 · Cited by 427
Rabiul Islam, M., Mahfuz-Ur-Rahman, A. M., Muttaqi, K. M., & Sutanto, D. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2018.2878885 · Cited by 178
“6 shows the circuit diagram of a cycloconverter based modified CHB converter for medium-voltage grid integration of solar PV power plants [38].”
BackgroundMethodIncorporating battery energy storage systems into multi-MW grid connected PV systems
Rallabandi, V., Akeyo, O. M., Jewell, N., & Ionel, D. M. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2864696 · Cited by 115
Metadata
- Authors
- Essakiappan, S., Krishnamoorthy, H. S., Enjeti, P., Balog, R. S., & Ahmed, S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-07
- Volume
- 30
- Issue
- 7
- Pages
- 3674-3684
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2164267947
- Cited by
- 161
- References
- 22
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.