The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Small-Signal Stability Analysis of Three-Phase AC Systems in the Presence of Constant Power Loads Based on Measured d-q Frame Impedances
Abstract
Small-signal stability is of great concern for electrical power systems with a large number of regulated power converters. In the case of dc systems, stability can be predicted by examining the locus described by the ratio of the source and load impedances in the complex plane per the Nyquist stability criterion. For balanced three-phase ac systems the same impedance-based method applies, for which this paper uses impedances in the synchronous rotating reference (d-q) frame. Small-signal stability can be determined by applying the generalized Nyquist stability criterion (GNC). This approach relies on the actual measurement of these impedances, which up to now has severely hindered its applicability. Addressing this shortcoming, this paper investigates the small-signal stability of a three-phase ac system using measured d-q frame impedances. The results obtained show how the stability at the ac interface can be easily and readily predicted using the measured impedances and the GNC, thus illustrating the practicality of the approach, and validating the use of ac impedances as a valuable dynamic analysis tool for ac system integration, in perfect dualism with the dc case.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Pulse Width Modulation for Power Converters
Holmes, D. G., & Lipo, T. A. (2003) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546284 · Cited by 2,384
Input filter considerations in design and application of switching regulators.
Middlebrook, R. D. (1976) · Medical Entomology and Zoology · Cited by 1,180
Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167
Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117
Small-Signal Methods for AC Distributed Power Systems–A Review
Sun, J. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2029859 · Cited by 712
Impedance specifications for stable DC distributed power systems
Feng, X., Liu, J., & Lee, F. C. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/63.988825 · Cited by 582
A method of defining the load impedance specification for a stable distributed power system
Wildrick, C. M., Lee, F. C., Cho, B. H., & Choi, B. (1995) · IEEE Transactions on Power Electronics · doi:10.1109/63.387992 · Cited by 520
Dynamic Stability of a Microgrid With an Active Load
Bottrell, N., Prodanovic, M., & Green, T. C. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2241455 · Cited by 416
A method of defining the load impedance specification for a stable distributed power system
Wildrick, C. M., Lee, F. C., Cho, B. H., & Choi, B. (2002) · Proceedings of IEEE Power Electronics Specialist Conference - PESC '93 · doi:10.1109/pesc.1993.472017 · Cited by 401
Cited by
Harmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282
Virtual Inertia: Current Trends and Future Directions
Tamrakar, U., Shrestha, D., Maharjan, M., Bhattarai, B., Hansen, T., & Tonkoski, R. (2017) · Applied Sciences · doi:10.3390/app7070654 · Cited by 640
Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters
Wen, B., Dong, D., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2419712 · Cited by 586
Self-citationWu, W., Liu, Y., He, Y., Chung, H. S.-H., Liserre, M., & Blaabjerg, F. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2714143 · Cited by 397
Evolution of microgrids with converter-interfaced generations: Challenges and opportunities
Hossain, M. A., Pota, H. R., Hossain, M. J., & Blaabjerg, F. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.01.038 · Cited by 309
Metadata
- Authors
- Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-10
- Volume
- 30
- Issue
- 10
- Pages
- 5952-5963
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1995879073
- Cited by
- 453
- References
- 18
- FWCI
- 30.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Small-Signal Stability Analysis of Three-Phase AC Systems in the Presence of Constant Power Loads Based on Measured d-q Frame Impedances. https://app.cochat.ai/papers/10.1109/tpel.2014.2378731
- The paper
- Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2015). Small-Signal Stability Analysis of Three-Phase AC Systems in the Presence of Constant Power Loads Based on Measured d-q Frame Impedances. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2014.2378731
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.