A Distributed Architecture Based on Microbank Modules With Self-Reconfiguration Control to Improve the Energy Efficiency in the Battery Energy Storage System
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper proposes a new distributed battery energy architecture based on the microbank module (MBM) for dc microgrids. The benefits of the proposed architecture include: 1) no voltage sharing problem and no overcharge/overdischarge problem; 2) high compatibility and reliability; 3) high energy utilization efficiency; 4) reduced volume and weight of the battery management system (BMS). The proposed MBM consists of a microbidirectional dc/dc converter, a micro-BMS and a cell bank. Moreover, taking advantage of the battery recovery effect, a self-reconfiguration discharge strategy is also proposed to further enhance the battery performance and discharge efficiency of the new battery energy storage system (BESS). To optimize the proposed control, an efficiency analytical model considering the battery recovery effect is proposed using the curve fitting method. Owing to the bidirectional capability, soft switching capability and high efficiency, the dual active bridge (DAB) converters are chosen as the microbidirectional dc/dc converters. A hybrid modulation strategy with variable switching frequency combining the conventional phase-shift modulation and triangular current modulation is proposed for the DAB converter to reduce the dominant loss and improve the efficiency in wide load range based on the minimum loss model. A 1.5-kW experimental testing platform consisting of four MBMs and four 12 V/100 Ah lithium battery modules was built to verify the proposed architecture with the control and the proposed model. The experimental results show that the discharge time of the proposed distributed BESS is increased significantly under wide operation condition with the self-reconfiguration control. The discharge efficiency of the BESS is improved by 7.1% with the idling time of 5 min under the power level of 1.5 kW.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accurate electrical battery model capable of predicting runtime and I-V performance
Chen, M., & Rincon-Mora, G. A. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874229 · Cited by 2,427
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932 · cited 1×
“To extend the ZVS range of the DAB converters, an extended phase shift control was proposed by modulating the duty cycle of either the primary side or the secondary side voltage [14].”
Method
Cited by
Battery‐supercapacitor hybrid energy storage system in standalone DC microgrids: areview
Jing, W., Hung Lai, C., Wong, S. H. W., & Wong, M. L. D. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0500 · Cited by 413
Wei, Z., Zhao, J., He, H., Ding, G., Cui, H., & Liu, L. (2021) · Journal of Power Sources · doi:10.1016/j.jpowsour.2021.229462 · Cited by 348
Xu, L., Guerrero, J., Lashab, A., Wei, B., Bazmohammadi, N., Vasquez, J., & Abusorrah, A. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3128417 · Cited by 262
Circulating Current and ZVS-on of a Dual Active Bridge DC-DC Converter: A Review
Shao, S., Chen, H., Wu, X., Zhang, J., & Sheng, K. (2019) · IEEE Access · doi:10.1109/access.2019.2911009 · Cited by 200
“Other applications including ESS interface converters [26], [27], airborne wind turbine [28], uninterrupted power supply (UPS) [29], and power load emulator [30] have also been reported.”
BackgroundNext-generation battery management systems: dynamic reconfiguration
Han, W., Wik, T., Kersten, A., Dong, G., & Zou, C. (2020) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2020.3002486 · Cited by 173
“For a quantitative investigation, the extended energy deliveries under different constant load power levels and resting periods are identified and compared in Figure 4, based on experimental test data gathered from [18].”
BackgroundMethodInfluential
Metadata
- Authors
- Zhang, Z., Cai, Y.-Y., Zhang, Y., Gu, D.-J., & Liu, Y.-F.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-01
- Volume
- 31
- Issue
- 1
- Pages
- 304-317
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2056571226
- Cited by
- 133
- References
- 3
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.