Control of Single-Phase Grid-Connected Converters with LCL Filters Using Recurrent Neural Network and Conventional Control Methods
The DOI matches its Crossref record.
Abstract
Single-phase grid-connected inverters are widely used to connect small-scale distributed renewable resources to the grid. However, unlike a three-phase system, control for a single-phase inverter is more challenging, especially when the inverter is used with an LCL filter. This paper proposes a novel recurrent neural network-based vector control method for a single-phase inverter with an LCL filter. The neural network is trained based on adaptive dynamic programming principle, and the objective of the training is to approximate optimal control. The Levenberg-Marquardt plus forward accumulation through time algorithm is developed for training the proposed recurrent neural network controller. The neural network vector control approach is compared with the conventional control methods, including the conventional PI-based vector control method and the PR-based control technique for single-phase inverters. Both the simulations and hardware experiments demonstrate the great advantages of the proposed neural network vector control over the conventional control methods. Compared with conventional control methods, the neural network control allows for low sampling rate and low switching frequency, while maintaining high performance in controlling a single-phase inverter. In addition, no specific damping policy is required to implement the proposed neural network vector control for an LCL-filter based single-phase inverter. The study shows that the neural network vector control is a robust control method, and can provide better control performance even when facing system parameter changes, while under this case, both the conventional PI-based vector control and the PR-based control failed to yield the acceptable results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An Overview of Artificial Intelligence Applications for Power Electronics
Zhao, S., Blaabjerg, F., & Wang, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3024914 · Cited by 947
Accurate photovoltaic power forecasting models using deep LSTM-RNN
Abdel-Nasser, M., & Mahmoud, K. (2019) · Neural Computing and Applications · doi:10.1007/s00521-017-3225-z · Cited by 752
Review of Ai Applications in Harmonic Analysis in Power Systems
Eslami, A., Negnevitsky, M., Franklin, E., & Lyden, S. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111897 · Cited by 109
Metadata
- Authors
- Fu, X., & Li, S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015
- Pages
- 1-1
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2277309690
- Cited by
- 167
- References
- 0
- FWCI
- 12.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Control of Single-Phase Grid-Connected Converters with LCL Filters Using Recurrent Neural Network and Conventional Control Methods. https://app.cochat.ai/papers/10.1109/tpel.2015.2490200
- The paper
- Fu, X., & Li, S. (2015). Control of Single-Phase Grid-Connected Converters with LCL Filters Using Recurrent Neural Network and Conventional Control Methods. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2015.2490200
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.