The DOI matches its Crossref record; the references it cites are not checked yet.
Synthesizing Virtual Oscillators to Control Islanded Inverters
Abstract
Virtual oscillator control (VOC) is a decentralized control strategy for islanded microgrids where inverters are regulated to emulate the dynamics of weakly nonlinear oscillators. Compared to droop control, which is only well defined in sinusoidal steady state, VOC is a time-domain controller that enables interconnected inverters to stabilize arbitrary initial conditions to a synchronized sinusoidal limit cycle. However, the nonlinear oscillators that are elemental to VOC cannot be designed with conventional linear-control design methods. We address this challenge by applying averaging- and perturbation-based nonlinear analysis methods to extract the sinusoidal steady-state and harmonic behavior of such oscillators. The averaged models reveal conclusive links between real- and reactive-power outputs and the terminal-voltage dynamics. Similarly, the perturbation methods aid in quantifying higher order harmonics. The resultant models are then leveraged to formulate a design procedure for VOC such that the inverter satisfies standard ac performance specifications related to voltage regulation, frequency regulation, dynamic response, and harmonic content. Experimental results for a single-phase 750 VA, 120 V laboratory prototype demonstrate the validity of the design approach. They also demonstrate that droop laws are, in fact, embedded within the equilibria of the nonlinear-oscillator dynamics. This establishes the backward compatibility of VOC in that, while acting on time-domain waveforms, it subsumes droop control in sinusoidal steady state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
References 37 · Cited by 334
Research works printed but not linked: 33
- wang, 0, Active and reactive power control schemes for distributed generation systems under voltage dips, Proc IEEE Energy Convers Congr Expo, 3564
- draper, 1981, Applied regression analysis
- 10.1109/TIE.2011.2163372 · DOI
- 10.1109/TSG.2013.2291912 · DOI
- 10.1109/19.481350 · DOI
- 10.1109/PESC.1989.48523 · DOI
- 10.1109/63.76811 · DOI
- 10.1109/TPEL.2008.2004272 · DOI
- 10.1109/63.484421 · DOI
- 10.1109/63.737600 · DOI
- 10.1109/TPEL.2006.876848 · DOI
- 10.1109/TIA.2005.847277 · DOI
- 10.1109/TPEL.2006.890003 · DOI
- dörfler, 2014, Breaking the hierarchy: Distributed control & economic optimality in microgrids, IEEE Transactions on Control of Network Systems
- 10.1109/TSG.2012.2197425 · DOI
- 10.1109/COMPEL.2015.7236441 · DOI
- 10.1109/TPEL.2013.2296292 · DOI
- 10.1109/IECON.2013.6699337 · DOI
- 10.1109/TAC.2015.2418400 · DOI
- 10.1016/j.automatica.2012.05.075 · DOI
- 10.1109/TPEL.2008.2005100 · DOI
- 10.1109/TCNS.2015.2503558 · DOI
- nayfeh, 2011, Introduction to Perturbation Techniques
- khalil, 2002, Nonlinear Systems
- 10.1109/PESGM.2012.6344905 · DOI
- 10.1016/j.automatica.2014.04.012 · DOI
- 10.1109/28.195899 · DOI
- 10.1109/TIE.2011.2146221 · DOI
- 10.1109/JPHOTOV.2013.2280953 · DOI
- 10.1109/TCSI.2013.2284180 · DOI
- krein, 1998, Elements of Power Electronics
- strogatz, 2001, Nonlinear Dynamics and Chaos With Applications to Physics Biology Chemistry and Engineering
- 10.1109/TPEL.2012.2199334 · DOI
Metadata
- Authors
- Johnson, B. B., Sinha, M., Ainsworth, N. G., Dorfler, F., & Dhople, S. V.
- Affiliations
- National Laboratory of the Rockies (US)
- University of Minnesota (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-08
- Volume
- 31
- Issue
- 8
- Pages
- 6002-6015
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2293277594
- Cited by
- 334
- References
- 37
- Citations by year
- 2026: 30 · 2025: 48 · 2024: 48 · 2023: 43 · 2022: 45 · 2021: 36 · 2020: 32 · 2019: 20 · 2018: 22 · 2017: 7 · 2016: 2
- FWCI
- 9.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- Laboratory Directed Research and Development
- U.S. Department of Energy (DE-AC36-08-GO28308)
- National Science Foundation under the CAREER Award (ECCS-CAR-1453921, ECCS-1509277)
- Office of Naval Research (N000141410639)
- ETH Zürich funds and the SNF Assistant Professor Energy (160573)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- virtual oscillator control, islanded microgrids, decentralized control, nonlinear oscillators, sinusoidal steady state, averaging method, perturbation analysis, harmonic content, droop control, inverter synchronization, voltage regulation, frequency regulation, single-phase inverter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review