ZVS Soft Switching Boundaries for Dual Active Bridge DC–DC Converters Using Frequency Domain Analysis
The DOI matches its Crossref record.
Abstract
Dual active bridge (DAB) converters offer an unmatched capability to transfer energy in either direction between two dc sources, while also providing galvanic isolation and high conversion efficiency. However, to operate at higher efficiencies, the bridges must operate with zero voltage switching (ZVS) over as wide an operating range as possible. The conventional approach to determine ZVS operation uses time domain analysis with ideal ac coupling inductances, which only approximately identifies the ZVS boundaries. This paper proposes a new approach using harmonic decomposition of the bridge switching patterns, which gives an explicit theoretical solution under all operating conditions, while also accommodating more complex ac coupling structures, practical impedance nonidealities, and the switching impact of dead-time and device capacitance. The methodology is confirmed by matching analytical predictions with experimental results for selected DAB systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
Modeling and Advanced Control of Dual-Active-Bridge DC–DC Converters: A Review
Shao, S., Chen, L., Shan, Z., Gao, F., Chen, H., Sha, D., & Dragičević, T. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3108157 · Cited by 488
Circulating Current and ZVS-on of a Dual Active Bridge DC-DC Converter: A Review
Shao, S., Chen, H., Wu, X., Zhang, J., & Sheng, K. (2019) · IEEE Access · doi:10.1109/access.2019.2911009 · Cited by 200
“multiple frequency components are derived in [64].”
Wang, Y., Song, Q., Zhao, B., Li, J., Sun, Q., & Liu, W. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2772833 · Cited by 71
“In addition, the DPS scheme in existing literature only optimizes a single characteristic, such as the current stress, power characteristic, efficiency characteristic or switching characteristic [28]–[31], and the multiobjective optimization scheme has not been considered yet.”
MethodKumar, A., Bhat, A. H., & Agarwal, P. (2017) · 2017 Recent Developments in Control, Automation & Power Engineering (RDCAPE) · doi:10.1109/rdcape.2017.8358301 · Cited by 14
Metadata
- Authors
- Riedel, J., Holmes, D. G., McGrath, B. P., & Teixeira, C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-04
- Volume
- 32
- Issue
- 4
- Pages
- 3166-3179
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2407946356
- Cited by
- 119
- References
- 0
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ZVS Soft Switching Boundaries for Dual Active Bridge DC–DC Converters Using Frequency Domain Analysis. https://app.cochat.ai/papers/10.1109/tpel.2016.2573856
- The paper
- Riedel, J., Holmes, D. G., McGrath, B. P., & Teixeira, C. (2017). ZVS Soft Switching Boundaries for Dual Active Bridge DC–DC Converters Using Frequency Domain Analysis. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2016.2573856
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.