Closed-Form Solution for Efficient ZVS Modulation of DAB Converters
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A directly employable closed-form analytical solution for the calculation of an efficient, full-operating-range zero voltage switching (ZVS) modulation scheme for bidirectional dual active bridge (DAB) dc-dc converters is presented. Contrary to the analytical ZVS modulation schemes previously proposed in literature, the amount of charge that is required to charge the nonlinear parasitic output capacitances of the switches during commutation is incorporated, ensuring complete commutation of the bridge legs and ZVS of the switching devices. Besides quasi-lossless ZVS, the resulting modulation scheme leads to near-minimum high-frequency circulating currents and thus, minimum conduction losses under the condition of ZVS and for given values of the inductances and transformer turns ratio. Although modifiable for other implementations, the method is demonstrated for a full-bridge full-bridge DAB as a core part of a single-phase, single-stage, bidirectional, isolated ac-dc converter. The resulting modulation scheme is compared with a ZVS modulation scheme calculated using a previously published numerical approach, proving its effectiveness. Experimental results obtained from a state-of-the-art, 3.7 kW converter prototype which interfaces a 400 V battery with the 230 V, 50 Hz utility grid are given to validate the theoretical analysis and practical feasibility of the proposed strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Solid-State Transformer Architecture Using AC–AC Dual-Active-Bridge Converter
Qin, H., & Kimball, J. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2204710 · Cited by 310 · cited 1×
“Besides high-performance dc–dc converters [1]–[4], DABs are often employed in ac–dc [5]–[9] and ac–ac [10] converter systems as well, either using a single-stage or a dual/multistage architecture.”
BackgroundWeise, N. D., Castelino, G., Basu, K., & Mohan, N. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293112 · Cited by 223 · cited 1×
“Besides high-performance dc–dc converters [1]–[4], DABs are often employed in ac–dc [5]–[9] and ac–ac [10] converter systems as well, either using a single-stage or a dual/multistage architecture.”
Background
Cited by
Hou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
Nonlinear $C_{oss}-V_{DS}$ Profile Based ZVS Range Calculation for Dual Active Bridge Converters
Liu, B., Davari, P., & Blaabjerg, F. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3003248 · Cited by 35
“App3: A third method in [10] is comparing the stored charges”
BackgroundMethodResultInfluential
Metadata
- Authors
- Everts, J.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-10
- Volume
- 32
- Issue
- 10
- Pages
- 7561-7576
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2559205551
- Cited by
- 175
- References
- 3
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.