An Open-Circuit Fault Diagnosis Approach for Single-Phase Three-Level Neutral-Point-Clamped Converters
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
This paper presents a model-based open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped (3LNPC) converters in electric railway application. The diagnosis algorithm, which only requires the signals existing in the control system, not only detects open-circuit faults but also identifies the faulty device among the transistors and clamping diodes. The mixed logical dynamic (MLD) model of the converter is built to estimate the grid current. The residual generated from the measured current subtracting the estimated one is analyzed under different open-circuit faults. According to the characteristics of the residual changing rate, the proposed approach allows fault localization. The proposed method is effective both in traction and regenerative braking operation and has fast diagnosis speed. Hardware-in-the-loop (HIL) experiments are carried out to verify the effectiveness of the proposed fault diagnosis algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of systems integrating logic, dynamics, and constraints
Bemporad, A., & Morari, M. (1999) · Automatica · doi:10.1016/s0005-1098(98)00178-2 · Cited by 3,066 · cited 1×
“The MLD model that mixes control transitions and condition transitions into logical expressions was proposed as a new modeling frame for hybrid system [30].”
MethodAn Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,019 · cited 1×
“It was reported in [4] that the semiconductor power device is the most fragile component in industry application.”
BackgroundA Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985 · cited 1×
“A lot of open-circuit fault diagnosismethods for threephase two-level converters have been proposed in recent years [6]–[10].”
BackgroundEstima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
Jung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
An, Q.-T., Sun, L.-Z., Zhao, K., & Sun, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052472 · Cited by 262 · cited 1×
“The traditional switching function model only considers control transitions [29].”
BackgroundMethod for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System
Choi, U.-M., Jeong, H.-G., Lee, K.-B., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2178435 · Cited by 241 · cited 1×
“Based on the approach in [11], the diagnosis method for grid-connected NPC inverters in [12] also uses the current-vector pattern and the localization of the faulty switch is realized by identifying the pattern angle and injecting the specific switching state.”
MethodCurrent Residual Vector-Based Open-Switch Fault Diagnosis of Inverters in PMSM Drive Systems
An, Q.-T., Sun, L., & Sun, L.-Z. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2360834 · Cited by 226 · cited 1×
“A lot of open-circuit fault diagnosismethods for threephase two-level converters have been proposed in recent years [6]–[10].”
BackgroundGou, B., Ge, X., Wang, S., Feng, X., Kuo, J. B., & Habetler, T. G. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465299 · Cited by 191 · cited 3×
“Condition monitoring and fault diagnosis for power devices are highly desirable and necessary to ensure safety and reducemaintenance costs in electric railway traction [5].”
BackgroundMethodInfluentialSelf-citationYoussef, A. B., El Khil, S. K., & Slama-Belkhodja, I. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2257862 · Cited by 186
Wu, F., & Zhao, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2422131 · Cited by 181
Lee, J.-S., Lee, K., & Blaabjerg, F. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2327151 · Cited by 172 · cited 1×
“In [14], the duration of the zero current is used to detect open-switch faults in wind turbine system.”
Caseiro, L. M. A., & Mendes, A. M. S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2341558 · Cited by 170 · cited 1×
“The diagnosis algorithm for three-level NPC rectifiers presented in [20] is based on the difference between the expected pole voltage and the measured one.”
BackgroundDetection Method for Open-Circuit Fault in Neutral-Point-Clamped Inverter Systems
Kim, T., Lee, W., & Hyun, D.-S. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2019775 · Cited by 139 · cited 1×
“The diagnosis technique in NPC inverters proposed in [18] uses a resistive voltage divider to monitor the pole voltage.”
MethodMendes, A. M. S., Abadi, M. B., & Cruz, S. M. A. (2013) · IET Power Electronics · doi:10.1049/iet-pel.2013.0416 · Cited by 95 · cited 1×
“proposed in [13].”
95/01538 Electric railway traction. Part 3. Traction power supplies
(1995) · Fuel and Energy Abstracts · doi:10.1016/0140-6701(95)93203-8 · Cited by 95
Fault Diagnoses for Industrial Grid-Connected Converters in the Power Distribution Systems
Kamel, T., Biletskiy, Y., & Chang, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2420627 · Cited by 82 · cited 1×
“The diagnosis method based on the output current in [27] just diagnoses the open-circuit fault and cannot achieve fault localization.”
MethodAnalysis and design of a three-levelPWM converter system for railway-traction applications
Shen, J., & Butterworth, N. (1997) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19971277 · Cited by 64
Detection and compensation of switch faults in a three level inverter
da Silva, E. R. C., Lima, W. S., de Oliveira, A. S., Jacobina, C. B., & Razik, H. (2006) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2006.1711955 · Cited by 45 · cited 1×
“In [17], the reference value and the measured value of the pole voltage are compared to detect the faulty half leg.”
MethodFault diagnosis and neutral point voltage control when the 3-level inverter faults occur
Son, H.-I., Kim, T., Kang, D.-W., & Hyun, D.-S. (2004) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2004.1354806 · Cited by 45 · cited 2×
“In [11], the fault diagnosis is achieved by comparing the faulty current-vector pattern with the normal pattern.”
MethodFault detection and tolerant control of 3-phase NPC active rectifier
Ku, H.-K., Im, W.-S., Kim, J.-M., & Suh, Y. (2012) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342206 · Cited by 36 · cited 1×
“Besides, other voltages such as line voltage [23] and dc voltage [24] are used for fault diagnosis.”
BackgroundOnline open‐switch fault diagnosis method in single‐phase PWM rectifiers
Ge, X., Pu, J., & Liu, Y. (2015) · Electronics Letters · doi:10.1049/el.2015.1194 · Cited by 32 · cited 1×
“An online open-switch fault diagnosis and localization method based on sampling theory was presented in [28].”
MethodSelf-citationA new fault detection method for NPC converters
Fazio, P., Maragliano, G., Marchesoni, M., & Parodi, G. (2011) · CINECA IRIS Institutial Research Information System (University of Genoa) · Cited by 29
Fault tolerance in active power filters, based on multilevel NPC topology
Lopes, P., & Mendes, A. M. S. (2012) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2012.6388786 · Cited by 8 · cited 1×
“Besides, other voltages such as line voltage [23] and dc voltage [24] are used for fault diagnosis.”
Background
Metadata
- Authors
- Ge, X., Pu, J., Gou, B., & Liu, Y.-C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2018-03
- Volume
- 33
- Issue
- 3
- Pages
- 2559-2570
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2605258224
- Cited by
- 158
- References
- 24
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.