Enhancing the Reliability of Modular Multilevel Converters Using Neutral Shift
The DOI matches its Crossref record; 7 of the 8 references it cites were found in a registry or an index.
Abstract
This letter presents an approach for modular multilevel converters that enables a stable operation with failed nonredundant modules. This is achieved by using a neutral shift with a dedicated power feed-forward control. The feasibility of the approach is verified by simulation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Cascaded Control System of the Modular Multilevel Converter for Feeding Variable-Speed Drives
Kolb, J., Kammerer, F., Gommeringer, M., & Braun, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2299894 · Cited by 269
Enhancing the reliability of modular medium-voltage drives
Hammond, P. W. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.803172 · Cited by 176 · cited 1×
“Another approach for maximizing the output voltage after module failure without redundant modules, called neutral shift, was primarily presented for the cascaded H-bridge converter by Hammond in [3].”
BackgroundExperimental Verification of a Modular Multilevel Cascade Inverter Based on Double-Star Bridge Cells
Thitichaiworakorn, N., Hagiwara, M., & Akagi, H. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2269896 · Cited by 160
A Postfault Strategy to Control the Modular Multilevel Converter Under Submodule Failure
Yang, Q., Qin, J., & Saeedifard, M. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2449875 · Cited by 69 · cited 1×
“[5] applying the neutral shift to the ac side was published, with regard to”
MethodKarwatzki, D., Baruschka, L., Dokus, M., Kucka, J., & Mertens, A. (2016) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2016.7695619 · Cited by 19 · cited 3×
“The control scheme presented in [9] extended by the feed-forward control and modulation with sorting based balancing were used for the converter control.”
MethodSelf-citationOptimised operating range of modular multilevel converters for AC/AC conversion with failed modules
Kucka, J., Karwatzki, D., & Mertens, A. (2015) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2015.7309453 · Cited by 17 · cited 1×
“The possibility to use this approach with MMC was first discussed by the authors of this letter in [4].”
MethodSelf-citationLi, J., Wu, X., Yao, X., Jing, L., Jin, X., Wu, W., Wang, X., & Wang, S. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854809 · Cited by 16 · cited 2×
“[6] presents a direct voltage injection in the star-point voltage (results in neutral shift at the dc side) for MMC.”
Background
Research works printed but not linked: 1
- marquardt, 2002, Modulares Stromrichterkonzept für Netzkupplungsanwendungen bei hohen Spannungen, ETG-Fachtagung, 155
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“power feedforward, can be applied to already implemented MMCs without requiring any additional hardware [122].”
BackgroundA Compact Modular Multilevel DC–DC Converter for High Step-Ratio MV and HV Use
Xiang, X., Zhang, X., Luth, T., Merlin, M., & Green, T. C. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793249 · Cited by 76
“The additional half-bridge SMs here are utilized to generate an adjustable control headroom for faster current transition, which has different roles and purposes in the operation with [39], [40]”
BackgroundMethodZhao, F., Xiao, G., Zhu, T., Xu, Z., Wu, Z., & Zhao, T. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2913696 · Cited by 64
“MMC brings favorable merits, such as perfect voltage waveform [4], high efficiency [5], and high capacity [6], which makes MMC widely applied”
BackgroundFarzamkia, S., Iman‐Eini, H., Noushak, M., & Hadizadeh, A. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2823659 · Cited by 61
“In comparison with [20], also, the amount of improvements is considerable, because this reference”
BackgroundMethodInfluentialXiao, H., Gan, H., Yang, P., Li, L., Li, D., Hao, Q., Huang, Y., Dai, L., & Liu, Y. (2023) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2023.3343693 · Cited by 54
“Shifting the neutral-point position increases the common-mode voltage on the neutral point, which can potentially damage the device [31], [32], [33], [34], [35], [36].”
BackgroundMeraj, M., Rahman, S., Iqbal, A., & Emadi, N. A. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2952206 · Cited by 49
“2952206 inverter [4], [5], the neutral point clamped (NPC) inverter [6], [7], the flying capacitor (FC) inverter [8], [9], and the modular multilevel converter (MMC) [10], [11].”
BackgroundDong, Y., Yang, H., Li, W., & He, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2833019 · Cited by 39
Farzamkia, S., Noushak, M., Iman‐Eini, H., Sadigh, A. K., & Farhangi, S. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2991998 · Cited by 30
“[24] shift the neutral-point voltage at the dc and ac sides.”
A New Hybrid Modular Multilevel Converter With Integrated Energy Storage
Zeng, W., Li, R., & Cai, X. (2019) · IEEE Access · doi:10.1109/access.2019.2940101 · Cited by 29
Last Developments and New Technologies in Solid-State Transformer
Liserre, M., Costa, L. F., Guo, Z., D’Amato, D., Queiroz, S. S., & Huang, A. Q. (2024) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg61800.2024.10667423 · Cited by 29
Modulation Strategies for Thermal Stress Control of CHB Inverters
Ko, Y., Kuprat, J., Pugliese, S., & Liserre, M. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3117917 · Cited by 26
Cui, S., Hu, J., & Doncker, R. D. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2911853 · Cited by 24
Farzamkia, S., Iman‐Eini, H., Sadigh, A. K., & Noushak, M. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3022984 · Cited by 23
“In the combined methods that utilize both the strategies [9], [30], [32], the optimum dc component is zero, and the best position for the neutral point is similar to the results of the NS method.”
BackgroundMethodResultInfluentialFu, J., Peyghami, S., Núñez, A. A., Blaabjerg, F., & Schutter, B. D. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3241317 · Cited by 16
“, high modularity and high power quality [4], modular multilevel converters (MMCs) are widely selected as power conversion devices in direct current transmission networks.”
BackgroundImproved Control of Capacitor Voltage Balancing in Modular Multilevel Converter Submodules
Lyu, Y., Zi, Y., & Li, X. (2024) · IEEE Access · doi:10.1109/access.2024.3350178 · Cited by 16
“…electronic device in the new power system, has the advantages of high efficiency, small fluctuation, and low electromagnetic interference compared with two-level converter, which has been applied in the fields of power transmission, renewable energy power generation and so on [1], [2], and [3].”
BackgroundCheng, H. L., Kong, J., Wang, P., & Wang, C. (2019) · IEEE Access · doi:10.1109/access.2019.2897799 · Cited by 17
“Benefit from these excellent performances, multilevel converter is considered as a kind of popular and competitive topology and has been commercialized in a lot of products [4], [5].”
BackgroundBenedetto, M. D., Ortenzi, F., Lidozzi, A., & Solero, L. (2021) · World Electric Vehicle Journal · doi:10.3390/wevj12010028 · Cited by 14
“However, in the last few years, power semiconductors have become more and more reliable [31,32] and their cost has drastically reduced compared to the cost of copper and iron, which are the main elements for making inductors or transformers.”
BackgroundLi, M., Jiang, X., Chen, C., Zhang, K., & Xiong, J. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3390421 · Cited by 14
“A new strategy combines dc injection and NS (CDCNS) [20], [21], which can maximize the phase voltage capability in certain fault situations, further alleviating the decrease in line voltages.”
BackgroundXiao, Q., Jin, Y., Dong, C., Jia, H., Hou, K., Chen, Q., Cupertino, A. F., Teodorescu, R., & Dragičević, T. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.106330 · Cited by 12
Wang, C., Zheng, Z., Wang, K., & Li, Y. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3146249 · Cited by 12
Design and Implementation of Lead–Carbon Battery Storage System
Li, J., Zhang, T., Duan, S., & Li, H. (2019) · IEEE Access · doi:10.1109/access.2019.2904067 · Cited by 12
Fagundes, T. A., Fuzato, G. H. F., Magossi, R. F. Q., Oliveira, A. L. R., & Machado, R. Q. (2024) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2024.3446911 · Cited by 10
“Inaddition, cascade and modular multilevel converters are the topologies of module-level fault-tolerant which are divided in neutral shift [13], [14], dc-bus voltage regulation [15], and redundant series or parallel module [16], [17], [18].”
BackgroundLashab, A., Séra, D., & Guerrero, J. M. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8912551 · Cited by 9
“Modular multilevel converter topologies have several advantages such as low switching frequency, high output voltage quality allowing the use of a much less sizable output filter, reduced dv/dt leading to less electromagnetic interference (EMI), and fault tolerance [3].”
BackgroundGeng, Z., Yang, Y. B., Xiao, Y., & Xie, W. (2024) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2024.3414301 · Cited by 8
“The FT in [8] further improves the methods in [6], [7] based on neutral shift.”
BackgroundMethodProtection schemes and settings of DC distribution systems
Ke, J., Chen, C., Zhao, Q., Feng, T., Tianshu, B., & Liu, H. (2020) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2019.1800 · Cited by 7
Huang, W., Zha, X., Liu, F., Liu, W., Zhuang, Y., & Huang, Y. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3179477 · Cited by 5
“Based on classic MMCs, a method of controlling the neural shift is proposed in [22], which enhances its reliability with the failed nonredundant modules.”
MethodResilient Operation for Grid-Connected Cascaded H-Bridge Multilevel Inverter Based on Neutral Offset
Zhu, J., Li, Y., Lehman, B., & Peng, F. Z. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3589466 · Cited by 4
“Kucka et al. [9] extends the neutral shift by applying it to both the ac and dc sides of an modular multilevel converter (MMC), injecting ac and dc zero-sequence components, but this requires specialized power control due to power interactions and limits its applicability to other modular…”
Modelling and Simulation of H-type Multilevel Inverter with Secondary Circuit
Jha, V. (2021) · Emerging Trends in Industry 4.0 (ETI 4.0) · doi:10.1109/eti4.051663.2021.9619359 · Cited by 3
Dynamic Phasor Model of Modular Multilevel Converters High Voltage DC transmission
Chen, S., Qingwui, G., & Qin, L. (2022) · International Conference on Energy, Electrical and Power Engineering (CEEPE) · doi:10.1109/ceepe55110.2022.9783292 · Cited by 3
“Meanwhile, similar to the literature [10], [11], the MMC average value model also ignores the differences in sub-module capacity, so this model is not suitable for verifying the voltage balance algorithm in different capacitor.”
MethodResultFault-Tolerant Method of Modular Railway Power Conditioner Based on DC Bus Voltage Regulation
Ding, H., Ma, F., Han, R. G., Zhang, C., & Wong, M. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3285987 · Cited by 3
“The other method is the neutral point shift fault-tolerant control [19], [20], [21], which realizes the maximum output line voltage by selecting the amplitude and phase angle of the phase voltage of the healthy phase leg.”
MethodNing, G., Dai, B., Su, M., Shu, L., & Xiong, W. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3377466 · Cited by 3
“The last type of DCT is based on the modular multilevel converter (MMC) structure [13], [14], [15].”
BackgroundResearch of modular multilevel converter with phase-shifted pulse-width modulation
Kozakevych, I., & Siyanko, R. (2021) · E3S Web of Conferences · doi:10.1051/e3sconf/202128005009 · Cited by 2
An improved mixed-cell submodule based modular multilevel converter (MMC) suitable for HVDC System
Chaudhari, H., & Darji, P. B. (2025) · International Journal of Electronics · doi:10.1080/00207217.2025.2506019 · Cited by 1
“redundancy, which guarantees a superior level of dependability and accessibility for the MMC system (Kucka et al., 2017).”
Zhu, J., Li, Y., Lehman, B., & Peng, F. Z. (2026) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2026.3678276 · Cited by 2
“In [18], neutral shifting is extended to both the AC and DC sides in MMCs, but this requires coordinated power control, limiting its general applicability.”
Research on SOC balance strategy of STEKF battery based on MMC-BESS model
Zhu, X., Li, Y., Yang, H., Xue, J., Cheng, Z., Zhang, Q., & Tao, Y. (2020) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/510/2/022025 · Cited by 1
“In the past more than one decade, due to high modularization of MMC topological structure, single sub-module has the characteristics of low voltage level, low switching frequency and small harmonic distortion rate of inverter output voltage, and it is generally applied in the fields of HVDC power transmission, AC-DC h…”
BackgroundReliability Study of Wind Turbine Power Converter with Multiple Wind Speed
Zhang, J., Sun, H., Lv, D., Zhiran, D., & Gao, Z. (2020) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/440/3/032117
“[5] Through analyses and uses neutral shift to improve the reliability of power converter.”
MethodThe Fault-Tolerant Control Strategy of DC-side for Three-phase to Single-phase Cascaded Converter
Wang, Z., Zeng, L., & He, X. (2022) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itecasia-pacific56316.2022.9942178
“Therefore, after some certain fault occurs in the power electronic converter, how to make the converter continue to realize the working ability through a certain fault tolerant control method, so as to improve the reliability of the converter, such fault tolerant schemes have attracted wide attention of researchers [3…”
BackgroundFault‐Tolerant Converter Design for Photovoltaic System
Malik, A., & Haque, A. (2022) · Wiley eBooks · doi:10.1002/9781119873785.ch8
Fault-Tolerant Strategy for MMC with Maximum Line-to-Line Voltage Capacity
Jiang, X., Li, M., Fang, X., Dong, Q., Zhang, K., & Xiong, J. (2023) · IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia) · doi:10.1109/icpsasia58343.2023.10294984
“The fundamental zero sequence voltage(FZSV) is injected to move the neutral point and reduce the output voltage amplitude of the fault arm to avoid over-modulation [12].”
BackgroundLi, L., Yuan, Y., Wen, B., & Cai, Z. (2024) · Research Square · doi:10.21203/rs.3.rs-4802558/v1
Analysis and Control of MMC with Zero-sequence Injection Fault-tolerant Strategy
Li, M., Jiao, J., & Zhang, K. (2024) · Power System and Green Energy Conference (PSGEC) · doi:10.1109/psgec62376.2024.10721175
“The strategy in [12] combines all of the above three components so that the theoretical maximum voltage can be obtained.”
BackgroundLi, X., Man, J., Wang, M., Zhu, B., & Liu, C. (2025) · IET Renewable Power Generation · doi:10.1049/rpg2.13196
Yao, F., Guo, C., & Sun, L. (2026) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.70581
Chaudhari, H. N., Vaghela, D. J., & Darji, P. B. (2026) · Engineering Research Express · doi:10.1088/2631-8695/aeba43
Metadata
- Authors
- Kucka, J., Karwatzki, D., & Mertens, A.
- Affiliations
- Leibniz University Hannover (DE)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-12
- Volume
- 32
- Issue
- 12
- Pages
- 8953-8957
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2607022059
- Cited by
- 43
- References
- 8
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 8 · 2023: 4 · 2022: 5 · 2021: 5 · 2020: 6 · 2019: 7 · 2018: 3
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- modular multilevel converter, module failure, converter reliability, fault tolerance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.