A General Constant Power Generation Algorithm for Photovoltaic Systems
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Photovoltaic power plants (PVPPs) typically operate by tracking the maximum power point (MPP) in order to maximize the conversion efficiency. However, with the continuous increase of installed grid-connected PVPPs, power system operators have been experiencing new challenges, such as overloading, overvoltages, and operation during grid-voltage disturbances. Consequently, constant power generation (CPG) is imposed by grid codes. An algorithm for the calculation of the photovoltaic panel voltage reference, which generates a constant power from the PVPP, is introduced in this paper. The key novelty of the proposed algorithm is its applicability for both single- and two-stage PVPPs and flexibility to move the operation point to the right or left side of the MPP. Furthermore, the execution frequency of the algorithm and voltage increments between consecutive operating points are modified based on a hysteresis band controller in order to obtain fast dynamic response under transients and low-power oscillation during steady-state operation. The performance of the proposed algorithm for both single- and two-stage PVPPs is examined on a 50-kVA simulation setup of these topologies. Moreover, experimental results on a 1-kVA PV system validate the effectiveness of the proposed algorithm under various operating conditions, demonstrating functionalities of the proposed CPG algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Comparative Study on Maximum Power Point Tracking Techniques for Photovoltaic Power Systems
Subudhi, B., & Pradhan, R. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2202294 · Cited by 1,867 · cited 1×
“Among all MPPT algorithms, perturb and observe (P&O) [11]–[13] and incre-”
BackgroundEvaluation of the Main MPPT Techniques for Photovoltaic Applications
de Brito, M. A. G., Galotto, L., Sampaio, L. P., Melo, G. D. A. E., & Canesin, C. A. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2198036 · Cited by 1,678 · cited 1×
“It is shown in [16] and [17] that the tracking performance of these two algorithms is similar under both static”
BackgroundOn the Perturb-and-Observe and Incremental Conductance MPPT Methods for PV Systems
Sera, D., Mathe, L., Kerekes, T., Spataru, S. V., & Teodorescu, R. (2013) · IEEE Journal of Photovoltaics · doi:10.1109/jphotov.2013.2261118 · Cited by 823 · cited 1×
“It is shown in [16] and [17] that the tracking performance of these two algorithms is similar under both static”
BackgroundTey, K. S., & Mekhilef, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2304921 · Cited by 528 · cited 3×
“Among all MPPT algorithms, perturb and observe (P&O) [11]–[13] and incremental conductance (INC) [14], [15] algorithms are the most commonly used.”
BackgroundA PSO-Based Global MPPT Technique for Distributed PV Power Generation
Renaudineau, H., Donatantonio, F., Fontchastagner, J., Petrone, G., Spagnuolo, G., Martin, J., & Pierfederici, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2336600 · Cited by 354
High-Performance Constant Power Generation in Grid-Connected PV Systems
Sangwongwanich, A., Yang, Y., & Blaabjerg, F. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465151 · Cited by 285 · cited 1×
“is a limitation in single-stage PVPPs for the movement of the operation point to the left side of MPP [28], [29].”
BackgroundSelf-citationJiang, Y., Abu Qahouq, J. A., & Haskew, T. A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2220158 · Cited by 222
Partial Shading Detection and Smooth Maximum Power Point Tracking of PV Arrays Under PSC
Ghasemi, M. A., Foroushani, H. M., & Parniani, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2504515 · Cited by 217
Mirhosseini, M., Pou, J., & Agelidis, V. G. (2015) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2347044 · Cited by 209 · cited 1×
“Similarly, CPG algorithms are investigated in [26] and [27] based on dc-link voltage control.”
Self-citationA Sensorless Power Reserve Control Strategy for Two-Stage Grid-Connected PV Systems
Sangwongwanich, A., Yang, Y., & Blaabjerg, F. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2648890 · Cited by 204 · cited 2×
“Therefore, the available algorithms in the literature [28]–[30] have been recommended to utilize the two-stage PVPP topology in order to achieve CPG”
MethodSelf-citation
Cited by
Haghighat, M., Niroomand, M., Dehghani Tafti, H., D. Townsend, C., & Fernando, T. (2024) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2022.000845 · Cited by 30
Metadata
- Authors
- Tafti, H. D., Maswood, A. I., Konstantinou, G., Pou, J., & Blaabjerg, F.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2018-05
- Volume
- 33
- Issue
- 5
- Pages
- 4088-4101
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2734595290
- Cited by
- 159
- References
- 28
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.